Alexander Bubovich, M. Vorobyov, I. Galkin, Tenuun Dovudon
{"title":"模块化多电平变换器与电池储能联用的质量评价","authors":"Alexander Bubovich, M. Vorobyov, I. Galkin, Tenuun Dovudon","doi":"10.1109/EDPE53134.2021.9604102","DOIUrl":null,"url":null,"abstract":"Battery energy storages nowadays are utilized in various applications. The similarity of these applications and multilevel nature of the batteries logically encourages building of the interface converters based on a multilevel scheme. This paper is devoted to the choice of the configuration of this scheme and its operation mode. Tentative quality evaluation is made based on the root-mean declination of output voltage from its reference (THD). MATLAB-Simulink simulation is chosen as a reasonable data collection method. The results of the simulation show that a trade-off configuration may include 3-4 levels with minor inter-level pulse width modulation. In the same time further investigation must be done in order to study the influence of other technical (losses) and economical parameters.","PeriodicalId":117091,"journal":{"name":"2021 International Conference on Electrical Drives & Power Electronics (EDPE)","volume":"310 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Quality Evaluation of Jointly Used Modular Multilevel Converters and Battery Energy Storages\",\"authors\":\"Alexander Bubovich, M. Vorobyov, I. Galkin, Tenuun Dovudon\",\"doi\":\"10.1109/EDPE53134.2021.9604102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Battery energy storages nowadays are utilized in various applications. The similarity of these applications and multilevel nature of the batteries logically encourages building of the interface converters based on a multilevel scheme. This paper is devoted to the choice of the configuration of this scheme and its operation mode. Tentative quality evaluation is made based on the root-mean declination of output voltage from its reference (THD). MATLAB-Simulink simulation is chosen as a reasonable data collection method. The results of the simulation show that a trade-off configuration may include 3-4 levels with minor inter-level pulse width modulation. In the same time further investigation must be done in order to study the influence of other technical (losses) and economical parameters.\",\"PeriodicalId\":117091,\"journal\":{\"name\":\"2021 International Conference on Electrical Drives & Power Electronics (EDPE)\",\"volume\":\"310 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Drives & Power Electronics (EDPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDPE53134.2021.9604102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Drives & Power Electronics (EDPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPE53134.2021.9604102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quality Evaluation of Jointly Used Modular Multilevel Converters and Battery Energy Storages
Battery energy storages nowadays are utilized in various applications. The similarity of these applications and multilevel nature of the batteries logically encourages building of the interface converters based on a multilevel scheme. This paper is devoted to the choice of the configuration of this scheme and its operation mode. Tentative quality evaluation is made based on the root-mean declination of output voltage from its reference (THD). MATLAB-Simulink simulation is chosen as a reasonable data collection method. The results of the simulation show that a trade-off configuration may include 3-4 levels with minor inter-level pulse width modulation. In the same time further investigation must be done in order to study the influence of other technical (losses) and economical parameters.