I. Kim, Chia-Pin Liang, Bo Yang, G. Makris, J. Desai, R. Gullapalli, Yu Chen
{"title":"并发多尺度成像:MRI指导下的神经外科光学相干断层扫描","authors":"I. Kim, Chia-Pin Liang, Bo Yang, G. Makris, J. Desai, R. Gullapalli, Yu Chen","doi":"10.1109/NEBEC.2013.164","DOIUrl":null,"url":null,"abstract":"We developed a novel platform based on a teleoperated robot to perform high-resolution optical coherence tomography (OCT) imaging under continuous MRI guidance. The combination of large-scale MRI tissue morphology and high-resolution OCT micro-architecture in a concurrent and co-registered manner has great potential to improve the accuracy of various neurosurgical procedures. In this study, we developed the first MRI-compatible OCT imaging system. We demonstrated that a thin OCT fiber probe (0.23 mm) integrated within surgical tools can provide microstructure information from the ROI under continuous MRI guidance. We tested the system's performance on chicken breast and simulated stereotactic neurosurgery on human brain ex vivo.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Concurrent Multi-scale Imaging: Optical Coherence Tomography under MRI Guidance for Neurosurgery\",\"authors\":\"I. Kim, Chia-Pin Liang, Bo Yang, G. Makris, J. Desai, R. Gullapalli, Yu Chen\",\"doi\":\"10.1109/NEBEC.2013.164\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a novel platform based on a teleoperated robot to perform high-resolution optical coherence tomography (OCT) imaging under continuous MRI guidance. The combination of large-scale MRI tissue morphology and high-resolution OCT micro-architecture in a concurrent and co-registered manner has great potential to improve the accuracy of various neurosurgical procedures. In this study, we developed the first MRI-compatible OCT imaging system. We demonstrated that a thin OCT fiber probe (0.23 mm) integrated within surgical tools can provide microstructure information from the ROI under continuous MRI guidance. We tested the system's performance on chicken breast and simulated stereotactic neurosurgery on human brain ex vivo.\",\"PeriodicalId\":153112,\"journal\":{\"name\":\"2013 39th Annual Northeast Bioengineering Conference\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 39th Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBEC.2013.164\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们开发了一种基于遥控机器人的新平台,用于在连续MRI引导下进行高分辨率光学相干断层扫描(OCT)成像。大尺度MRI组织形态学和高分辨率OCT微结构以并发和共注册的方式相结合,在提高各种神经外科手术的准确性方面具有很大的潜力。在这项研究中,我们开发了第一个mri兼容的OCT成像系统。我们证明了集成在手术工具中的薄OCT纤维探针(0.23 mm)可以在连续MRI引导下提供ROI的微观结构信息。我们在鸡胸脯上测试了系统的性能,并在离体人脑上模拟了立体定向神经外科手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Concurrent Multi-scale Imaging: Optical Coherence Tomography under MRI Guidance for Neurosurgery
We developed a novel platform based on a teleoperated robot to perform high-resolution optical coherence tomography (OCT) imaging under continuous MRI guidance. The combination of large-scale MRI tissue morphology and high-resolution OCT micro-architecture in a concurrent and co-registered manner has great potential to improve the accuracy of various neurosurgical procedures. In this study, we developed the first MRI-compatible OCT imaging system. We demonstrated that a thin OCT fiber probe (0.23 mm) integrated within surgical tools can provide microstructure information from the ROI under continuous MRI guidance. We tested the system's performance on chicken breast and simulated stereotactic neurosurgery on human brain ex vivo.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信