{"title":"电力系统谐波频率范围内电压互感器性能的建模","authors":"J. Luszcz, I. Moson","doi":"10.1109/ISNCC.2008.4627517","DOIUrl":null,"url":null,"abstract":"Many problems related to the voltage and current harmonics imposed in contemporary power systems are observed nowadays. The paper presents the voltage harmonic transfer capability of the voltage transformer usually used for the power quality measurement in the middle and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by experimental investigations. The results obtained prove that the wide band ripples of the voltage transformer transfer characteristic can result an extra measurement errors that should be taken into account in order to achieve applicable accuracy.","PeriodicalId":143815,"journal":{"name":"2008 International School on Nonsinusoidal Currents and Compensation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Modelling of voltage transformer performance in power system harmonic frequency range\",\"authors\":\"J. Luszcz, I. Moson\",\"doi\":\"10.1109/ISNCC.2008.4627517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many problems related to the voltage and current harmonics imposed in contemporary power systems are observed nowadays. The paper presents the voltage harmonic transfer capability of the voltage transformer usually used for the power quality measurement in the middle and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by experimental investigations. The results obtained prove that the wide band ripples of the voltage transformer transfer characteristic can result an extra measurement errors that should be taken into account in order to achieve applicable accuracy.\",\"PeriodicalId\":143815,\"journal\":{\"name\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNCC.2008.4627517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International School on Nonsinusoidal Currents and Compensation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNCC.2008.4627517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modelling of voltage transformer performance in power system harmonic frequency range
Many problems related to the voltage and current harmonics imposed in contemporary power systems are observed nowadays. The paper presents the voltage harmonic transfer capability of the voltage transformer usually used for the power quality measurement in the middle and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by experimental investigations. The results obtained prove that the wide band ripples of the voltage transformer transfer characteristic can result an extra measurement errors that should be taken into account in order to achieve applicable accuracy.