{"title":"SEC 132 kV输电线路带电作业人员极低频电磁场暴露评价","authors":"I. Habiballah, T. Abdel-Galil, M. Dawoud, C. Belhadj, M. A. Abdul-Majeed, T.A. Al-Betairi","doi":"10.1109/TDCLA.2006.311630","DOIUrl":null,"url":null,"abstract":"This paper presents an exposure assessment study for live-line workers exposed to transmission line power frequency electric and magnetic fields. A double circuit transmission line is selected. Practical exposure scenarios which represent actual working conditions for live-line workers have been identified. The charge simulation method has been adopted to compute the external electric field around the selected 132 kV transmission line. A method based on Ampere law has been chosen to compute the external magnetic field around the transmission line. Both methods are numerically solved using the EPRFs EMF Workstation software. A comparison between the values of external electric and magnetic fields, with the allowable exposure limits set by the international standards has been conducted. The paper concluded that the levels of workers exposures to extremely low frequency electric and magnetic fields are below the recommended international standards limits for the scenarios considered in this work","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"ELF Electric and Magnetic Fields Exposure Assessment of Live-Line Workers for 132 kV Transmission Line of SEC\",\"authors\":\"I. Habiballah, T. Abdel-Galil, M. Dawoud, C. Belhadj, M. A. Abdul-Majeed, T.A. Al-Betairi\",\"doi\":\"10.1109/TDCLA.2006.311630\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an exposure assessment study for live-line workers exposed to transmission line power frequency electric and magnetic fields. A double circuit transmission line is selected. Practical exposure scenarios which represent actual working conditions for live-line workers have been identified. The charge simulation method has been adopted to compute the external electric field around the selected 132 kV transmission line. A method based on Ampere law has been chosen to compute the external magnetic field around the transmission line. Both methods are numerically solved using the EPRFs EMF Workstation software. A comparison between the values of external electric and magnetic fields, with the allowable exposure limits set by the international standards has been conducted. The paper concluded that the levels of workers exposures to extremely low frequency electric and magnetic fields are below the recommended international standards limits for the scenarios considered in this work\",\"PeriodicalId\":406067,\"journal\":{\"name\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDCLA.2006.311630\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311630","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文介绍了输电线路工频电场和磁场对带电作业人员的暴露评价研究。选择双回路传输线。已经确定了代表现场工人实际工作条件的实际暴露情景。采用电荷模拟的方法,对选取的132 kV输电线路周围的外加电场进行了计算。采用基于安培定律的方法计算传输线周围的外磁场。采用EPRFs EMF Workstation软件对两种方法进行了数值求解。将外部电场和磁场值与国际标准规定的允许暴露限值进行了比较。该论文的结论是,工人暴露于极低频电场和磁场的水平低于本工作中考虑的情景所建议的国际标准限值
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ELF Electric and Magnetic Fields Exposure Assessment of Live-Line Workers for 132 kV Transmission Line of SEC
This paper presents an exposure assessment study for live-line workers exposed to transmission line power frequency electric and magnetic fields. A double circuit transmission line is selected. Practical exposure scenarios which represent actual working conditions for live-line workers have been identified. The charge simulation method has been adopted to compute the external electric field around the selected 132 kV transmission line. A method based on Ampere law has been chosen to compute the external magnetic field around the transmission line. Both methods are numerically solved using the EPRFs EMF Workstation software. A comparison between the values of external electric and magnetic fields, with the allowable exposure limits set by the international standards has been conducted. The paper concluded that the levels of workers exposures to extremely low frequency electric and magnetic fields are below the recommended international standards limits for the scenarios considered in this work
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信