中红外E-ELT仪器METIS温标单元:项目概述及现状

M. Rutowska, T. Sharma, M. Wiest, S. Graf, C. Straubmeier, S. Rost, L. Labadie, A. Eckart, L. Burtscher, T. Agócs, D. Lesman, R. Stuik, A. Glauser, B. Brandl, F. Bettonvil
{"title":"中红外E-ELT仪器METIS温标单元:项目概述及现状","authors":"M. Rutowska, T. Sharma, M. Wiest, S. Graf, C. Straubmeier, S. Rost, L. Labadie, A. Eckart, L. Burtscher, T. Agócs, D. Lesman, R. Stuik, A. Glauser, B. Brandl, F. Bettonvil","doi":"10.1117/12.2562219","DOIUrl":null,"url":null,"abstract":"The warm calibration unit (WCU) is one subsystem of the future METIS instrument on the European Extremely Large Telescope (E-ELT). Operating at daytime temperature, the WCU is mounted above the main cryostat of METIS and will be employed as calibration reference for science observations, as well as for verification and alignment purposes during the AIT phase. The WCU is designed and constructed at the University of Cologne, partner in the METIS consortium. The WCU, together with the full METIS instrument, went recently through a successful preliminary design review (PDR) phase at ESO and is entering now the Phase C of the project. In this paper, we present the current status of the WCU and summarize the mostly mechanical and optical engineering work. We adopted a hexapod unit to interface with the METIS cryostat and a CFRP-based optical bench to optimally cope with alignment flexure. We develop the case for fiber-fed laser sources feeding the integrating sphere for spectral calibration of the LM-Spectrograph of METIS. We detail the activity foreseen for Phase C including the optical tolerances analysis, the eigenfrequency and earthquake analysis and a preparation of the sub-system MAIT work, finishing the paper with a short overview of the WCU future plans.","PeriodicalId":215000,"journal":{"name":"Ground-based and Airborne Instrumentation for Astronomy VIII","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Warm calibration unit of the mid-infrared E-ELT instrument METIS: overview and current status of the project\",\"authors\":\"M. Rutowska, T. Sharma, M. Wiest, S. Graf, C. Straubmeier, S. Rost, L. Labadie, A. Eckart, L. Burtscher, T. Agócs, D. Lesman, R. Stuik, A. Glauser, B. Brandl, F. Bettonvil\",\"doi\":\"10.1117/12.2562219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The warm calibration unit (WCU) is one subsystem of the future METIS instrument on the European Extremely Large Telescope (E-ELT). Operating at daytime temperature, the WCU is mounted above the main cryostat of METIS and will be employed as calibration reference for science observations, as well as for verification and alignment purposes during the AIT phase. The WCU is designed and constructed at the University of Cologne, partner in the METIS consortium. The WCU, together with the full METIS instrument, went recently through a successful preliminary design review (PDR) phase at ESO and is entering now the Phase C of the project. In this paper, we present the current status of the WCU and summarize the mostly mechanical and optical engineering work. We adopted a hexapod unit to interface with the METIS cryostat and a CFRP-based optical bench to optimally cope with alignment flexure. We develop the case for fiber-fed laser sources feeding the integrating sphere for spectral calibration of the LM-Spectrograph of METIS. We detail the activity foreseen for Phase C including the optical tolerances analysis, the eigenfrequency and earthquake analysis and a preparation of the sub-system MAIT work, finishing the paper with a short overview of the WCU future plans.\",\"PeriodicalId\":215000,\"journal\":{\"name\":\"Ground-based and Airborne Instrumentation for Astronomy VIII\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ground-based and Airborne Instrumentation for Astronomy VIII\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2562219\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ground-based and Airborne Instrumentation for Astronomy VIII","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2562219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

热校准单元(WCU)是未来欧洲超大望远镜(E-ELT) METIS仪器的一个子系统。WCU在白天温度下工作,安装在METIS的主低温恒温器上方,将用作科学观测的校准参考,以及在AIT阶段的验证和校准目的。WCU由科隆大学设计和建造,该大学是METIS联盟的合作伙伴。WCU和完整的METIS仪器最近在ESO成功地通过了初步设计审查(PDR)阶段,现在正在进入项目的C阶段。本文介绍了WCU的研究现状,并对主要的机械和光学工程方面的工作进行了总结。我们采用了一个六足单元来连接METIS低温恒温器和一个基于cfrp的光学平台,以最佳地应对对准挠度。本文提出了光纤馈送激光源馈送积分球用于METIS lm光谱仪光谱定标的实例。我们详细介绍了C阶段的预期活动,包括光学公差分析、特征频率和地震分析以及子系统MAIT工作的准备,最后简要概述了WCU的未来计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Warm calibration unit of the mid-infrared E-ELT instrument METIS: overview and current status of the project
The warm calibration unit (WCU) is one subsystem of the future METIS instrument on the European Extremely Large Telescope (E-ELT). Operating at daytime temperature, the WCU is mounted above the main cryostat of METIS and will be employed as calibration reference for science observations, as well as for verification and alignment purposes during the AIT phase. The WCU is designed and constructed at the University of Cologne, partner in the METIS consortium. The WCU, together with the full METIS instrument, went recently through a successful preliminary design review (PDR) phase at ESO and is entering now the Phase C of the project. In this paper, we present the current status of the WCU and summarize the mostly mechanical and optical engineering work. We adopted a hexapod unit to interface with the METIS cryostat and a CFRP-based optical bench to optimally cope with alignment flexure. We develop the case for fiber-fed laser sources feeding the integrating sphere for spectral calibration of the LM-Spectrograph of METIS. We detail the activity foreseen for Phase C including the optical tolerances analysis, the eigenfrequency and earthquake analysis and a preparation of the sub-system MAIT work, finishing the paper with a short overview of the WCU future plans.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信