非接触动态模式原子力显微镜:非线性原子力的影响

S. Das, P. Sreeram, A. Raychaudhuri, T. Sai, L. Brar
{"title":"非接触动态模式原子力显微镜:非线性原子力的影响","authors":"S. Das, P. Sreeram, A. Raychaudhuri, T. Sai, L. Brar","doi":"10.1109/NANOEL.2006.1609771","DOIUrl":null,"url":null,"abstract":"We present an experimental investigation of the variation of the amplitude of vibrating microcantilever, as a function of distance (h) between the microcantilever and the sample in a Dynamic Force Microscopy (DFM) and explain the observations with a theoretical model. In DFM, as the cantilever tip approaches the sample, neither the force nor the response of the cantilever is in the linear regime. We present an exact numerical solution to the equation of motion of the oscillations of the microcantilever and present a quantitative explanation to the observed force versus distance curves, in terms of the resonance curves. We show that the change in the resonance frequency of the cantilever due to the atomic forces is highly nonlinear.","PeriodicalId":220722,"journal":{"name":"2006 IEEE Conference on Emerging Technologies - Nanoelectronics","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Non-Contact Dynamic Mode Atomic Force Microscope : Effects of nonlinear atomic forces\",\"authors\":\"S. Das, P. Sreeram, A. Raychaudhuri, T. Sai, L. Brar\",\"doi\":\"10.1109/NANOEL.2006.1609771\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present an experimental investigation of the variation of the amplitude of vibrating microcantilever, as a function of distance (h) between the microcantilever and the sample in a Dynamic Force Microscopy (DFM) and explain the observations with a theoretical model. In DFM, as the cantilever tip approaches the sample, neither the force nor the response of the cantilever is in the linear regime. We present an exact numerical solution to the equation of motion of the oscillations of the microcantilever and present a quantitative explanation to the observed force versus distance curves, in terms of the resonance curves. We show that the change in the resonance frequency of the cantilever due to the atomic forces is highly nonlinear.\",\"PeriodicalId\":220722,\"journal\":{\"name\":\"2006 IEEE Conference on Emerging Technologies - Nanoelectronics\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Conference on Emerging Technologies - Nanoelectronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NANOEL.2006.1609771\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Conference on Emerging Technologies - Nanoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANOEL.2006.1609771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

我们在动态力显微镜(DFM)中对微悬臂梁振动振幅的变化进行了实验研究,作为微悬臂梁与样品之间距离(h)的函数,并用理论模型解释了观察结果。在DFM中,当悬臂梁尖端靠近试样时,悬臂梁的力和响应都不处于线性状态。我们提出了微悬臂梁振荡运动方程的精确数值解,并根据共振曲线对观察到的力与距离曲线进行了定量解释。结果表明,原子力对悬臂梁谐振频率的影响是高度非线性的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-Contact Dynamic Mode Atomic Force Microscope : Effects of nonlinear atomic forces
We present an experimental investigation of the variation of the amplitude of vibrating microcantilever, as a function of distance (h) between the microcantilever and the sample in a Dynamic Force Microscopy (DFM) and explain the observations with a theoretical model. In DFM, as the cantilever tip approaches the sample, neither the force nor the response of the cantilever is in the linear regime. We present an exact numerical solution to the equation of motion of the oscillations of the microcantilever and present a quantitative explanation to the observed force versus distance curves, in terms of the resonance curves. We show that the change in the resonance frequency of the cantilever due to the atomic forces is highly nonlinear.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信