A. V. Kraiski, T. Mironova, T. Sultanov, V. A. Postnikov
{"title":"比色法测量标准格式和RAW格式光辐射波长分布的可能性","authors":"A. V. Kraiski, T. Mironova, T. Sultanov, V. A. Postnikov","doi":"10.1109/CAOL.2013.6657632","DOIUrl":null,"url":null,"abstract":"We compare results of the colorimetric method use for measurements of the wavelength distribution from digital images in standard formats (BMP, JPEG, TIFF) and in RAW-format. It is shown that with the use of the last one the operating range is several times larger (up to 455-625 nm).","PeriodicalId":189618,"journal":{"name":"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The possibilities of the colorimetric method for measuring of wavelength's distribution of light radiation in standard and the RAW formats\",\"authors\":\"A. V. Kraiski, T. Mironova, T. Sultanov, V. A. Postnikov\",\"doi\":\"10.1109/CAOL.2013.6657632\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We compare results of the colorimetric method use for measurements of the wavelength distribution from digital images in standard formats (BMP, JPEG, TIFF) and in RAW-format. It is shown that with the use of the last one the operating range is several times larger (up to 455-625 nm).\",\"PeriodicalId\":189618,\"journal\":{\"name\":\"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CAOL.2013.6657632\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Conference on Advanced Optoelectronics and Lasers (CAOL 2013)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CAOL.2013.6657632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The possibilities of the colorimetric method for measuring of wavelength's distribution of light radiation in standard and the RAW formats
We compare results of the colorimetric method use for measurements of the wavelength distribution from digital images in standard formats (BMP, JPEG, TIFF) and in RAW-format. It is shown that with the use of the last one the operating range is several times larger (up to 455-625 nm).