{"title":"减小直流电容的永磁同步电机驱动直流电容在线估计","authors":"B. Zhou, Gaolin Wang, Runfeng Gao, Guoqiang Zhang, Nannan Zhao, Dianguo Xu","doi":"10.1109/IECON48115.2021.9589375","DOIUrl":null,"url":null,"abstract":"In order to avoid the failure of electrolytic capacitor due to the influence of ambient temperature, film capacitors are applied in the DC-link of permanent magnet synchronous motor (PMSM) drive systems. In this paper, an online estimation method of DC-link capacitance is proposed for the electrolytic capacitorless motor drive system. The power signals of the drive system are analyzed, and the characteristic frequency of the DC-link capacitance power is determined. The instantaneous capacitor power is obtained by the sampled grid input power and the reconstructed inverter power, which is determined by the DC-link voltage and inverter input current. The components of capacitor power and the result of multiplication of DC-link voltage and its derivative at the expected frequency are obtained to calculate the DC-link capacitance by a band-pass filter. The estimation process can be carried out when the system operates normally, and no additional sensors are required. The experimental results verify the effectiveness of the proposed method.","PeriodicalId":443337,"journal":{"name":"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Online Estimation of DC-Link Capacitance for Permanent Magnet Synchronous Motor Drive with Reduced DC-Link Capacitor\",\"authors\":\"B. Zhou, Gaolin Wang, Runfeng Gao, Guoqiang Zhang, Nannan Zhao, Dianguo Xu\",\"doi\":\"10.1109/IECON48115.2021.9589375\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to avoid the failure of electrolytic capacitor due to the influence of ambient temperature, film capacitors are applied in the DC-link of permanent magnet synchronous motor (PMSM) drive systems. In this paper, an online estimation method of DC-link capacitance is proposed for the electrolytic capacitorless motor drive system. The power signals of the drive system are analyzed, and the characteristic frequency of the DC-link capacitance power is determined. The instantaneous capacitor power is obtained by the sampled grid input power and the reconstructed inverter power, which is determined by the DC-link voltage and inverter input current. The components of capacitor power and the result of multiplication of DC-link voltage and its derivative at the expected frequency are obtained to calculate the DC-link capacitance by a band-pass filter. The estimation process can be carried out when the system operates normally, and no additional sensors are required. The experimental results verify the effectiveness of the proposed method.\",\"PeriodicalId\":443337,\"journal\":{\"name\":\"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON48115.2021.9589375\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON48115.2021.9589375","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Online Estimation of DC-Link Capacitance for Permanent Magnet Synchronous Motor Drive with Reduced DC-Link Capacitor
In order to avoid the failure of electrolytic capacitor due to the influence of ambient temperature, film capacitors are applied in the DC-link of permanent magnet synchronous motor (PMSM) drive systems. In this paper, an online estimation method of DC-link capacitance is proposed for the electrolytic capacitorless motor drive system. The power signals of the drive system are analyzed, and the characteristic frequency of the DC-link capacitance power is determined. The instantaneous capacitor power is obtained by the sampled grid input power and the reconstructed inverter power, which is determined by the DC-link voltage and inverter input current. The components of capacitor power and the result of multiplication of DC-link voltage and its derivative at the expected frequency are obtained to calculate the DC-link capacitance by a band-pass filter. The estimation process can be carried out when the system operates normally, and no additional sensors are required. The experimental results verify the effectiveness of the proposed method.