G. Bosco, M. Garcocz, K. Lind, U. Pogliano, G. Rietveld, V. Tarasso, B. Voljc, V. N. Zachovalova
{"title":"高达100khz的大电流分流器的相位比较","authors":"G. Bosco, M. Garcocz, K. Lind, U. Pogliano, G. Rietveld, V. Tarasso, B. Voljc, V. N. Zachovalova","doi":"10.1109/CPEM.2010.5545149","DOIUrl":null,"url":null,"abstract":"A comparison of the phase of existing shunts for currents between 10 A and 100 A and frequencies from 500 Hz to 100 kHz has been organized. The measurements were performed at INRIM using a first prototype of a new type of phase comparator and a step-up method for the data processing. The results of the relative measurements have shown a good repeatability, but the method for the evaluation of the reference value still needs some improvement.","PeriodicalId":222495,"journal":{"name":"CPEM 2010","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Phase comparison of high current shunts up to 100 kHz\",\"authors\":\"G. Bosco, M. Garcocz, K. Lind, U. Pogliano, G. Rietveld, V. Tarasso, B. Voljc, V. N. Zachovalova\",\"doi\":\"10.1109/CPEM.2010.5545149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A comparison of the phase of existing shunts for currents between 10 A and 100 A and frequencies from 500 Hz to 100 kHz has been organized. The measurements were performed at INRIM using a first prototype of a new type of phase comparator and a step-up method for the data processing. The results of the relative measurements have shown a good repeatability, but the method for the evaluation of the reference value still needs some improvement.\",\"PeriodicalId\":222495,\"journal\":{\"name\":\"CPEM 2010\",\"volume\":\"46 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CPEM 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2010.5545149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CPEM 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2010.5545149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Phase comparison of high current shunts up to 100 kHz
A comparison of the phase of existing shunts for currents between 10 A and 100 A and frequencies from 500 Hz to 100 kHz has been organized. The measurements were performed at INRIM using a first prototype of a new type of phase comparator and a step-up method for the data processing. The results of the relative measurements have shown a good repeatability, but the method for the evaluation of the reference value still needs some improvement.