Wang Qi, Zhang Wenchao, Tang Yong
{"title":"直流应急电源控制在提高特高压交流示范工程输电能力中的应用研究","authors":"Wang Qi, Zhang Wenchao, Tang Yong","doi":"10.1109/POWERCON.2010.5666686","DOIUrl":null,"url":null,"abstract":"The steady-state stability of UHV demonstration project is low due to large interconnection impedance. In this paper, a DC emergency power control strategy is proposed to improve UHV demonstration project transmission capability by using DC fast adjustment to restrain the tie -line power variation and decrease UHV power oscillation peak value. The simulation results show that the North and Central China interconnection power grid can keep synchronization stability during disturbance or power shortage, after the proposed DC emergency power control strategy has been applied. The proposed control strategy can be widely applied in China to effectively improve the stability of North and Central China interconnection power grid during disturbance.","PeriodicalId":169553,"journal":{"name":"2010 International Conference on Power System Technology","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Research on application of DC emergency power control to improve the transmission capacity of UHV AC demonstration project\",\"authors\":\"Wang Qi, Zhang Wenchao, Tang Yong\",\"doi\":\"10.1109/POWERCON.2010.5666686\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The steady-state stability of UHV demonstration project is low due to large interconnection impedance. In this paper, a DC emergency power control strategy is proposed to improve UHV demonstration project transmission capability by using DC fast adjustment to restrain the tie -line power variation and decrease UHV power oscillation peak value. The simulation results show that the North and Central China interconnection power grid can keep synchronization stability during disturbance or power shortage, after the proposed DC emergency power control strategy has been applied. The proposed control strategy can be widely applied in China to effectively improve the stability of North and Central China interconnection power grid during disturbance.\",\"PeriodicalId\":169553,\"journal\":{\"name\":\"2010 International Conference on Power System Technology\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Power System Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2010.5666686\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2010.5666686","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

特高压示范工程由于互联阻抗大,稳态稳定性较低。本文提出了一种直流应急功率控制策略,通过直流快速调节抑制并线功率变化,降低特高压功率振荡峰值,提高特高压示范工程输电能力。仿真结果表明,采用所提出的直流应急功率控制策略后,华北和华中互联电网能够在干扰或缺电情况下保持同步稳定。所提出的控制策略可以在中国广泛应用,有效地提高华北和华中互联电网在扰动时的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on application of DC emergency power control to improve the transmission capacity of UHV AC demonstration project
The steady-state stability of UHV demonstration project is low due to large interconnection impedance. In this paper, a DC emergency power control strategy is proposed to improve UHV demonstration project transmission capability by using DC fast adjustment to restrain the tie -line power variation and decrease UHV power oscillation peak value. The simulation results show that the North and Central China interconnection power grid can keep synchronization stability during disturbance or power shortage, after the proposed DC emergency power control strategy has been applied. The proposed control strategy can be widely applied in China to effectively improve the stability of North and Central China interconnection power grid during disturbance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信