自由空间辐射测量标定用局部放电仿真器的比较研究

A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover
{"title":"自由空间辐射测量标定用局部放电仿真器的比较研究","authors":"A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover","doi":"10.1109/IConAC.2016.7604938","DOIUrl":null,"url":null,"abstract":"Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.","PeriodicalId":375052,"journal":{"name":"2016 22nd International Conference on Automation and Computing (ICAC)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Comparative study of Partial Discharge emulators for the calibration of Free-Space radiometric measurements\",\"authors\":\"A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover\",\"doi\":\"10.1109/IConAC.2016.7604938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.\",\"PeriodicalId\":375052,\"journal\":{\"name\":\"2016 22nd International Conference on Automation and Computing (ICAC)\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 22nd International Conference on Automation and Computing (ICAC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IConAC.2016.7604938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 22nd International Conference on Automation and Computing (ICAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IConAC.2016.7604938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

采用自由空间辐射测量法(FSR)和基于IEC 60270标准的电接触测量技术同时测量局部放电。几种类型的局部放电源是专门构造的:两个内部的局部放电模拟器和一个浮动电极类型的模拟器。源的激励是交流的,辐射信号是用宽带双锥天线捕获的。演示了PD源的校准。利用PD校准装置确定了PD源的有效辐射功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative study of Partial Discharge emulators for the calibration of Free-Space radiometric measurements
Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信