A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover
{"title":"自由空间辐射测量标定用局部放电仿真器的比较研究","authors":"A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover","doi":"10.1109/IConAC.2016.7604938","DOIUrl":null,"url":null,"abstract":"Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.","PeriodicalId":375052,"journal":{"name":"2016 22nd International Conference on Automation and Computing (ICAC)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Comparative study of Partial Discharge emulators for the calibration of Free-Space radiometric measurements\",\"authors\":\"A. Jaber, P. Lazaridis, B. Saeed, Yong Zhang, David Khan, D. Upton, H. Ahmed, P. Mather, M. D. F. Q. Turnell, R. Atkinson, M. Judd, I. Glover\",\"doi\":\"10.1109/IConAC.2016.7604938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.\",\"PeriodicalId\":375052,\"journal\":{\"name\":\"2016 22nd International Conference on Automation and Computing (ICAC)\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 22nd International Conference on Automation and Computing (ICAC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IConAC.2016.7604938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 22nd International Conference on Automation and Computing (ICAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IConAC.2016.7604938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative study of Partial Discharge emulators for the calibration of Free-Space radiometric measurements
Partial discharge is measured simultaneously using free-space radiometry (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. Several types of PD (Partial Discharge) sources are specially constructed: two internal PD emulators and an emulator of the floating-electrode type. The excitation applied to the source is AC and the radiated signal is captured using a wideband biconical antenna. The calibration of PD sources is demonstrated. Effective radiated power of the PD source using a PD calibration device is determined.