P. Balachandar, S. Ganesan, N. Jayakumar, S. Subramanian
{"title":"基于蚁狮优化器的互联电力系统多燃料调度:考虑联络线限制的多燃料调度","authors":"P. Balachandar, S. Ganesan, N. Jayakumar, S. Subramanian","doi":"10.4018/IJEOE.2017070102","DOIUrl":null,"url":null,"abstract":"The electrical power generation from fossil fuel releases several contaminants into the air and this become excrescent if the generating unit is fed by Multiple Fuel Sources MFS.The ever more stringent environmental regulations have forced the power producers to produce electricity not only at the cheapest price but also at the minimum level of pollutant emissions. Inclusion of this issue in the operational task is a welcome perspective. The cost effective and environmental responsive power system operations in the presence of MFS can be recognized as a multi-objective constrained optimization problem with conflicting operational objectives. The modern meta-heuristic algorithm namely, Ant Lion Optimizer ALO has been applied for the first time to obtain the feasible solution. The fuzzy decision-making mechanism has been integrated to determine the Best Compromise Solution BCS in the multi-objective framework. The intended algorithm is implemented on the standard test systems considering valve-point effects, CO2 emission and tie-line limits.","PeriodicalId":246250,"journal":{"name":"Int. J. Energy Optim. Eng.","volume":"141 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Multi-Fuel Power Dispatch in an Interconnected Power System using Ant Lion Optimizer: Multi-Fuel Dispatch Considering Tie-Line Limits\",\"authors\":\"P. Balachandar, S. Ganesan, N. Jayakumar, S. Subramanian\",\"doi\":\"10.4018/IJEOE.2017070102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The electrical power generation from fossil fuel releases several contaminants into the air and this become excrescent if the generating unit is fed by Multiple Fuel Sources MFS.The ever more stringent environmental regulations have forced the power producers to produce electricity not only at the cheapest price but also at the minimum level of pollutant emissions. Inclusion of this issue in the operational task is a welcome perspective. The cost effective and environmental responsive power system operations in the presence of MFS can be recognized as a multi-objective constrained optimization problem with conflicting operational objectives. The modern meta-heuristic algorithm namely, Ant Lion Optimizer ALO has been applied for the first time to obtain the feasible solution. The fuzzy decision-making mechanism has been integrated to determine the Best Compromise Solution BCS in the multi-objective framework. The intended algorithm is implemented on the standard test systems considering valve-point effects, CO2 emission and tie-line limits.\",\"PeriodicalId\":246250,\"journal\":{\"name\":\"Int. J. Energy Optim. Eng.\",\"volume\":\"141 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Int. J. Energy Optim. Eng.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/IJEOE.2017070102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Energy Optim. Eng.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/IJEOE.2017070102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Multi-Fuel Power Dispatch in an Interconnected Power System using Ant Lion Optimizer: Multi-Fuel Dispatch Considering Tie-Line Limits
The electrical power generation from fossil fuel releases several contaminants into the air and this become excrescent if the generating unit is fed by Multiple Fuel Sources MFS.The ever more stringent environmental regulations have forced the power producers to produce electricity not only at the cheapest price but also at the minimum level of pollutant emissions. Inclusion of this issue in the operational task is a welcome perspective. The cost effective and environmental responsive power system operations in the presence of MFS can be recognized as a multi-objective constrained optimization problem with conflicting operational objectives. The modern meta-heuristic algorithm namely, Ant Lion Optimizer ALO has been applied for the first time to obtain the feasible solution. The fuzzy decision-making mechanism has been integrated to determine the Best Compromise Solution BCS in the multi-objective framework. The intended algorithm is implemented on the standard test systems considering valve-point effects, CO2 emission and tie-line limits.