{"title":"非接触式心电图干电极设计","authors":"Peinan Mao, Hongwei Lv, Huiling Peng","doi":"10.1109/AEMCSE50948.2020.00129","DOIUrl":null,"url":null,"abstract":"We present a gel-free, non-contact dry electrode based on a PCB for electrocardiogram(ECG) recording. We designed the electrode as a 1.5-inch round plate. The fabricated electrode has an amplifier with low power consumption and high-impedance input and a high-frequency filter circuit. Integrated circuit of the fabricated electrode can reduce noise pickup and increase gain. Through this experiment we compared the ECG obtained from a disposable wet electrode and the ECG obtained from dry electrode, and both of all can see clear ECG recorded signals.","PeriodicalId":246841,"journal":{"name":"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non-Contact Electrocardiogram Dry Electrode Design\",\"authors\":\"Peinan Mao, Hongwei Lv, Huiling Peng\",\"doi\":\"10.1109/AEMCSE50948.2020.00129\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a gel-free, non-contact dry electrode based on a PCB for electrocardiogram(ECG) recording. We designed the electrode as a 1.5-inch round plate. The fabricated electrode has an amplifier with low power consumption and high-impedance input and a high-frequency filter circuit. Integrated circuit of the fabricated electrode can reduce noise pickup and increase gain. Through this experiment we compared the ECG obtained from a disposable wet electrode and the ECG obtained from dry electrode, and both of all can see clear ECG recorded signals.\",\"PeriodicalId\":246841,\"journal\":{\"name\":\"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEMCSE50948.2020.00129\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEMCSE50948.2020.00129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
We present a gel-free, non-contact dry electrode based on a PCB for electrocardiogram(ECG) recording. We designed the electrode as a 1.5-inch round plate. The fabricated electrode has an amplifier with low power consumption and high-impedance input and a high-frequency filter circuit. Integrated circuit of the fabricated electrode can reduce noise pickup and increase gain. Through this experiment we compared the ECG obtained from a disposable wet electrode and the ECG obtained from dry electrode, and both of all can see clear ECG recorded signals.