{"title":"使用无噪声电子泵校正灵敏电流表","authors":"S. Giblin, G. Yamahata, A. Fujiwara, M. Kataoka","doi":"10.1109/CPEM49742.2020.9191724","DOIUrl":null,"url":null,"abstract":"We compare an electron pump and an ultrastable low-noise current amplifier (ULCA) as reference current sources for calibrating a high-gain current preamplifier at pA-level currents. Using the electron pump on a quantized current plateau, the current noise is dominated by the device under test, whereas using the ULCA, the larger ULCA noise is the biggest contribution. In a 20-second measurement at a nominal current of 3.2 pA, the preamplifier gain is resolved with a relative type A uncertainty of $5\\times 10^{-5}$ using the pump, and $2\\times 10^{-4}$ using the ULCA.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration of Sensitive Ammeters Using a Noiseless Electron Pump\",\"authors\":\"S. Giblin, G. Yamahata, A. Fujiwara, M. Kataoka\",\"doi\":\"10.1109/CPEM49742.2020.9191724\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We compare an electron pump and an ultrastable low-noise current amplifier (ULCA) as reference current sources for calibrating a high-gain current preamplifier at pA-level currents. Using the electron pump on a quantized current plateau, the current noise is dominated by the device under test, whereas using the ULCA, the larger ULCA noise is the biggest contribution. In a 20-second measurement at a nominal current of 3.2 pA, the preamplifier gain is resolved with a relative type A uncertainty of $5\\\\times 10^{-5}$ using the pump, and $2\\\\times 10^{-4}$ using the ULCA.\",\"PeriodicalId\":373216,\"journal\":{\"name\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM49742.2020.9191724\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191724","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibration of Sensitive Ammeters Using a Noiseless Electron Pump
We compare an electron pump and an ultrastable low-noise current amplifier (ULCA) as reference current sources for calibrating a high-gain current preamplifier at pA-level currents. Using the electron pump on a quantized current plateau, the current noise is dominated by the device under test, whereas using the ULCA, the larger ULCA noise is the biggest contribution. In a 20-second measurement at a nominal current of 3.2 pA, the preamplifier gain is resolved with a relative type A uncertainty of $5\times 10^{-5}$ using the pump, and $2\times 10^{-4}$ using the ULCA.