{"title":"固定转速风力发电机对配电系统静电压稳定性的影响","authors":"M. H. Haque","doi":"10.1109/ICDRET.2016.7421499","DOIUrl":null,"url":null,"abstract":"More and more small-scale wind generators are being connected to distribution systems. Higher degree of penetration of wind generators can significantly change many operating characteristics of the system including voltage profile and hence voltage stability. This paper proposes a straightforward method of static voltage stability assessment of a radial distribution system with fixed-speed wind generators. Time varying system demand and measured wind data over a period of one year are considered. The effectiveness of the proposed method is then evaluated on a 12.66-kV radial distribution system consisting of 32 buses and the results obtained are systematically described.","PeriodicalId":365312,"journal":{"name":"2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Impacts of fixed speed wind generators on static voltage stability of distribution systems\",\"authors\":\"M. H. Haque\",\"doi\":\"10.1109/ICDRET.2016.7421499\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"More and more small-scale wind generators are being connected to distribution systems. Higher degree of penetration of wind generators can significantly change many operating characteristics of the system including voltage profile and hence voltage stability. This paper proposes a straightforward method of static voltage stability assessment of a radial distribution system with fixed-speed wind generators. Time varying system demand and measured wind data over a period of one year are considered. The effectiveness of the proposed method is then evaluated on a 12.66-kV radial distribution system consisting of 32 buses and the results obtained are systematically described.\",\"PeriodicalId\":365312,\"journal\":{\"name\":\"2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDRET.2016.7421499\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 4th International Conference on the Development in the in Renewable Energy Technology (ICDRET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDRET.2016.7421499","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impacts of fixed speed wind generators on static voltage stability of distribution systems
More and more small-scale wind generators are being connected to distribution systems. Higher degree of penetration of wind generators can significantly change many operating characteristics of the system including voltage profile and hence voltage stability. This paper proposes a straightforward method of static voltage stability assessment of a radial distribution system with fixed-speed wind generators. Time varying system demand and measured wind data over a period of one year are considered. The effectiveness of the proposed method is then evaluated on a 12.66-kV radial distribution system consisting of 32 buses and the results obtained are systematically described.