马卡瓜-卡亚奥-克拉利塔斯400千伏线路的保护理念

H. Pineda, J. L. Flores
{"title":"马卡瓜-卡亚奥-克拉利塔斯400千伏线路的保护理念","authors":"H. Pineda, J. L. Flores","doi":"10.1109/TDCLA.2006.311570","DOIUrl":null,"url":null,"abstract":"In order to protect in case of fault on the Macagua-Callao-Claritas 400 kV line that supply energy to Eletronorte utilities in Brazil, a particular protection scheme was designed under a fault detection table, which allowed to evaluate the different scenarios in case of the internal and external fault. This scheme are made up of relays of distance and directional overcurrent in the three substations (Macagua-Callao-Claritas), operating in a special permissive overreach scheme with weak infeed, using an optical fiber connection as communication way between each terminal for teleprotection equipments to send and receive the necessary permissive signals to active the scheme. Additionally, for transient faults, the scheme has a single phase auto reclosing which increases the continuity of service of our customer Eletronorte in Brazil","PeriodicalId":406067,"journal":{"name":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Philosophy of Protection for The Macagua-Callao-Claritas 400 kV Line\",\"authors\":\"H. Pineda, J. L. Flores\",\"doi\":\"10.1109/TDCLA.2006.311570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to protect in case of fault on the Macagua-Callao-Claritas 400 kV line that supply energy to Eletronorte utilities in Brazil, a particular protection scheme was designed under a fault detection table, which allowed to evaluate the different scenarios in case of the internal and external fault. This scheme are made up of relays of distance and directional overcurrent in the three substations (Macagua-Callao-Claritas), operating in a special permissive overreach scheme with weak infeed, using an optical fiber connection as communication way between each terminal for teleprotection equipments to send and receive the necessary permissive signals to active the scheme. Additionally, for transient faults, the scheme has a single phase auto reclosing which increases the continuity of service of our customer Eletronorte in Brazil\",\"PeriodicalId\":406067,\"journal\":{\"name\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDCLA.2006.311570\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDCLA.2006.311570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了在巴西为Eletronorte公用设施供电的Macagua-Callao-Claritas 400千伏线路发生故障时进行保护,在故障检测表下设计了一种特殊的保护方案,可以在内部和外部故障的情况下评估不同的情况。该方案由三个变电站(Macagua-Callao-Claritas)中的距离继电器和定向过流继电器组成,在弱进给的特殊允许超伸方案中运行,每个终端之间使用光纤连接作为通信方式,远程保护设备发送和接收必要的允许信号以激活该方案。此外,对于暂态故障,该方案具有单相自动重合闸,从而增加了我们在巴西的客户Eletronorte的服务连续性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Philosophy of Protection for The Macagua-Callao-Claritas 400 kV Line
In order to protect in case of fault on the Macagua-Callao-Claritas 400 kV line that supply energy to Eletronorte utilities in Brazil, a particular protection scheme was designed under a fault detection table, which allowed to evaluate the different scenarios in case of the internal and external fault. This scheme are made up of relays of distance and directional overcurrent in the three substations (Macagua-Callao-Claritas), operating in a special permissive overreach scheme with weak infeed, using an optical fiber connection as communication way between each terminal for teleprotection equipments to send and receive the necessary permissive signals to active the scheme. Additionally, for transient faults, the scheme has a single phase auto reclosing which increases the continuity of service of our customer Eletronorte in Brazil
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信