S. Giblin, G. Yamahata, J. Williams, S. Rozhko, T. Janssen, A. Fujiwara, M. Kataoka
{"title":"缩放电流从一个GHz电子泵使用CCC","authors":"S. Giblin, G. Yamahata, J. Williams, S. Rozhko, T. Janssen, A. Fujiwara, M. Kataoka","doi":"10.1109/CPEM.2016.7540624","DOIUrl":null,"url":null,"abstract":"We demonstrate the scaling of the current from a tunable-barrier electron pump using a cryogenic current comparator (CCC) with a turns ratio of 1:22592. The amplified current flows in a calibrated 100 kΩ resistor, and the voltage drop across this resistor is directly compared against a binary Josephson array. The experimental setup constitutes a prototype realization of the metrology triangle proposed more than 15 years ago.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Scaling the current from a GHz electron pump using a CCC\",\"authors\":\"S. Giblin, G. Yamahata, J. Williams, S. Rozhko, T. Janssen, A. Fujiwara, M. Kataoka\",\"doi\":\"10.1109/CPEM.2016.7540624\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrate the scaling of the current from a tunable-barrier electron pump using a cryogenic current comparator (CCC) with a turns ratio of 1:22592. The amplified current flows in a calibrated 100 kΩ resistor, and the voltage drop across this resistor is directly compared against a binary Josephson array. The experimental setup constitutes a prototype realization of the metrology triangle proposed more than 15 years ago.\",\"PeriodicalId\":415488,\"journal\":{\"name\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2016.7540624\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Scaling the current from a GHz electron pump using a CCC
We demonstrate the scaling of the current from a tunable-barrier electron pump using a cryogenic current comparator (CCC) with a turns ratio of 1:22592. The amplified current flows in a calibrated 100 kΩ resistor, and the voltage drop across this resistor is directly compared against a binary Josephson array. The experimental setup constitutes a prototype realization of the metrology triangle proposed more than 15 years ago.