异步电动机在不平衡状态下的双FEM-Simulink分析

L. Livadaru, A. Simion, S. Vlasceanu, A. Munteanu, D. Irimia
{"title":"异步电动机在不平衡状态下的双FEM-Simulink分析","authors":"L. Livadaru, A. Simion, S. Vlasceanu, A. Munteanu, D. Irimia","doi":"10.1109/OPTIM.2012.6231783","DOIUrl":null,"url":null,"abstract":"This paper presents a dual approach concerning the influence of unbalanced supply voltage on the three-phase induction motor operation. On one hand, a FEM-based analysis examines the ill effects upon the magnetic field, as main concern, and a few electric and mechanical parameters. On the other hand, a study of the transitory regime (including no-load startup and sudden loading) is employed under Simulink environment. To this aim, an original equation system, developed by the authors and called “in total fluxes” is used. The both analyses take into discussion a 3.5kW cage induction motor and two unbalanced degrees. Among other effects, the results put in view the huge influence of the voltage unbalances upon the torque and speed smoothness, which finally turns into vibrations and noise.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dual FEM-Simulink analysis of induction motor operating under unbalanced state\",\"authors\":\"L. Livadaru, A. Simion, S. Vlasceanu, A. Munteanu, D. Irimia\",\"doi\":\"10.1109/OPTIM.2012.6231783\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a dual approach concerning the influence of unbalanced supply voltage on the three-phase induction motor operation. On one hand, a FEM-based analysis examines the ill effects upon the magnetic field, as main concern, and a few electric and mechanical parameters. On the other hand, a study of the transitory regime (including no-load startup and sudden loading) is employed under Simulink environment. To this aim, an original equation system, developed by the authors and called “in total fluxes” is used. The both analyses take into discussion a 3.5kW cage induction motor and two unbalanced degrees. Among other effects, the results put in view the huge influence of the voltage unbalances upon the torque and speed smoothness, which finally turns into vibrations and noise.\",\"PeriodicalId\":382406,\"journal\":{\"name\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"volume\":\"61 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OPTIM.2012.6231783\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了电源电压不平衡对三相异步电动机运行影响的双重方法。一方面,基于有限元的分析检查了对磁场的不良影响,作为主要关注点,以及一些电气和机械参数。另一方面,在Simulink环境下研究了系统的过渡状态(包括空载启动和突然加载)。为此目的,使用了作者开发的称为“总通量”的原始方程组。这两种分析都考虑了3.5kW笼型感应电动机和两个不平衡度。在其他影响中,结果表明电压不平衡对转矩和速度平稳性的巨大影响,最终转化为振动和噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual FEM-Simulink analysis of induction motor operating under unbalanced state
This paper presents a dual approach concerning the influence of unbalanced supply voltage on the three-phase induction motor operation. On one hand, a FEM-based analysis examines the ill effects upon the magnetic field, as main concern, and a few electric and mechanical parameters. On the other hand, a study of the transitory regime (including no-load startup and sudden loading) is employed under Simulink environment. To this aim, an original equation system, developed by the authors and called “in total fluxes” is used. The both analyses take into discussion a 3.5kW cage induction motor and two unbalanced degrees. Among other effects, the results put in view the huge influence of the voltage unbalances upon the torque and speed smoothness, which finally turns into vibrations and noise.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信