{"title":"用于抑制风力发电波动的风电场聚合与分布式储能系统性能比较","authors":"Wei Li, G. Joós","doi":"10.1109/PES.2007.386249","DOIUrl":null,"url":null,"abstract":"As wind penetration increases, the adverse impact of wind power fluctuations on the system frequency becomes significant. Especially for isolated or weakly connected small- scale power systems, the wind power induced system frequency deviations might exceed beyond the safe range set by utilities. Coupling energy storage system (ESS) to wind energy can smooth the wind power. The ESS in a wind farm can be either aggregated or distributed configured. This paper examines the performance differences of the two ESS configurations. The evaluation of the ESS performance is based on the fluctuation harmonic content (FHC) which quantitatively describes how fluctuant the power is. The system frequency deviations induced by untreated and filtered wind powers are investigated in a study system with different generation mixes. This research shows the distributed ESS configuration is as effective as its aggregated counterpart in wind power smoothing and system frequency deviation reduction.","PeriodicalId":380613,"journal":{"name":"2007 IEEE Power Engineering Society General Meeting","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Performance Comparison of Aggregated and Distributed Energy Storage Systems in a Wind Farm For Wind Power Fluctuation Suppression\",\"authors\":\"Wei Li, G. Joós\",\"doi\":\"10.1109/PES.2007.386249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As wind penetration increases, the adverse impact of wind power fluctuations on the system frequency becomes significant. Especially for isolated or weakly connected small- scale power systems, the wind power induced system frequency deviations might exceed beyond the safe range set by utilities. Coupling energy storage system (ESS) to wind energy can smooth the wind power. The ESS in a wind farm can be either aggregated or distributed configured. This paper examines the performance differences of the two ESS configurations. The evaluation of the ESS performance is based on the fluctuation harmonic content (FHC) which quantitatively describes how fluctuant the power is. The system frequency deviations induced by untreated and filtered wind powers are investigated in a study system with different generation mixes. This research shows the distributed ESS configuration is as effective as its aggregated counterpart in wind power smoothing and system frequency deviation reduction.\",\"PeriodicalId\":380613,\"journal\":{\"name\":\"2007 IEEE Power Engineering Society General Meeting\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2007.386249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2007.386249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

随着风侵度的增大,风电功率波动对系统频率的不利影响变得显著。特别是对于孤立或弱连接的小型电力系统,风力发电引起的系统频率偏差可能超出公用事业公司设定的安全范围。风能耦合储能系统(ESS)可以实现风力发电的平稳运行。风电场的ESS可采用聚合配置或分布式配置。本文考察了两种ESS配置的性能差异。对ESS性能的评价是基于波动谐波含量(FHC),它定量地描述了功率的波动程度。在不同发电组合的研究系统中,研究了未处理风电和过滤风电对系统频率偏差的影响。研究表明,分布式ESS配置在风电平滑和降低系统频率偏差方面与聚合ESS配置同样有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Comparison of Aggregated and Distributed Energy Storage Systems in a Wind Farm For Wind Power Fluctuation Suppression
As wind penetration increases, the adverse impact of wind power fluctuations on the system frequency becomes significant. Especially for isolated or weakly connected small- scale power systems, the wind power induced system frequency deviations might exceed beyond the safe range set by utilities. Coupling energy storage system (ESS) to wind energy can smooth the wind power. The ESS in a wind farm can be either aggregated or distributed configured. This paper examines the performance differences of the two ESS configurations. The evaluation of the ESS performance is based on the fluctuation harmonic content (FHC) which quantitatively describes how fluctuant the power is. The system frequency deviations induced by untreated and filtered wind powers are investigated in a study system with different generation mixes. This research shows the distributed ESS configuration is as effective as its aggregated counterpart in wind power smoothing and system frequency deviation reduction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信