{"title":"不同P300拼写方法的脑电图P300检测性能研究","authors":"Sergio López Bernal, Enrique Tomás Martínez Beltrán, Mario Quiles Pérez, Ruben Ortega Romero, Alberto Huertas Celdrán, G. Pérez","doi":"10.1109/ismict56646.2022.9828283","DOIUrl":null,"url":null,"abstract":"Brain-Computer Interfaces (BCIs) are bidirectional devices that have allowed people to control computers or external devices through their brain activity. The P300 Speller is one of the most widely used BCI applications, where subjects can transmit textual information mentally with satisfactory performance. However, the P300 Speller still has room for improvement in practical use, such as selecting the best balance between accuracy and speed. Based on a lack of literature in this direction, this study evaluates two distinct approaches to the P300 Speller. The first is based on rows and columns following the traditional implementation, while the second is based on regions, employing subsets of characters during spelling. In both approaches, the effects of two different stimulus presentation parameters (the number of repetitions per stimulus and the interval between them) on the accuracy and performance efficiency of the P300 Speller are studied. The results show that both approaches obtain similar values in terms of detection performance, obtaining around 75% F1-score for predicting a character with four series of 12 blinks per character. In addition, the region-based approach presents a more robust scheme for false predictions, maintaining a similar spelling duration. The theoretical study performed indicates that spelling a character requires around one minute.","PeriodicalId":436823,"journal":{"name":"2022 IEEE 16th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"242 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study of P300 Detection Performance by Different P300 Speller Approaches Using Electroencephalography\",\"authors\":\"Sergio López Bernal, Enrique Tomás Martínez Beltrán, Mario Quiles Pérez, Ruben Ortega Romero, Alberto Huertas Celdrán, G. Pérez\",\"doi\":\"10.1109/ismict56646.2022.9828283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Brain-Computer Interfaces (BCIs) are bidirectional devices that have allowed people to control computers or external devices through their brain activity. The P300 Speller is one of the most widely used BCI applications, where subjects can transmit textual information mentally with satisfactory performance. However, the P300 Speller still has room for improvement in practical use, such as selecting the best balance between accuracy and speed. Based on a lack of literature in this direction, this study evaluates two distinct approaches to the P300 Speller. The first is based on rows and columns following the traditional implementation, while the second is based on regions, employing subsets of characters during spelling. In both approaches, the effects of two different stimulus presentation parameters (the number of repetitions per stimulus and the interval between them) on the accuracy and performance efficiency of the P300 Speller are studied. The results show that both approaches obtain similar values in terms of detection performance, obtaining around 75% F1-score for predicting a character with four series of 12 blinks per character. In addition, the region-based approach presents a more robust scheme for false predictions, maintaining a similar spelling duration. The theoretical study performed indicates that spelling a character requires around one minute.\",\"PeriodicalId\":436823,\"journal\":{\"name\":\"2022 IEEE 16th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"volume\":\"242 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 16th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ismict56646.2022.9828283\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 16th International Symposium on Medical Information and Communication Technology (ISMICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ismict56646.2022.9828283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

脑机接口(bci)是一种双向设备,它允许人们通过大脑活动来控制计算机或外部设备。P300拼写器是使用最广泛的脑机接口应用程序之一,被试可以在心理上传递文本信息,并且表现令人满意。然而,P300拼写器在实际使用中仍有改进的空间,例如在准确性和速度之间选择最佳平衡。基于缺乏这方面的文献,本研究评估了P300拼写器的两种不同方法。第一个是基于传统实现的行和列,而第二个是基于区域,在拼写过程中使用字符子集。在这两种方法中,研究了两种不同的刺激呈现参数(每个刺激的重复次数和它们之间的间隔)对P300拼写准确率和表现效率的影响。结果表明,两种方法在检测性能方面获得了相似的值,在预测一个字符时获得了大约75%的f1分,每个字符有四个系列的12次眨眼。此外,基于区域的方法提供了一个更健壮的错误预测方案,保持了相似的拼写持续时间。理论研究表明,拼写一个字符大约需要一分钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of P300 Detection Performance by Different P300 Speller Approaches Using Electroencephalography
Brain-Computer Interfaces (BCIs) are bidirectional devices that have allowed people to control computers or external devices through their brain activity. The P300 Speller is one of the most widely used BCI applications, where subjects can transmit textual information mentally with satisfactory performance. However, the P300 Speller still has room for improvement in practical use, such as selecting the best balance between accuracy and speed. Based on a lack of literature in this direction, this study evaluates two distinct approaches to the P300 Speller. The first is based on rows and columns following the traditional implementation, while the second is based on regions, employing subsets of characters during spelling. In both approaches, the effects of two different stimulus presentation parameters (the number of repetitions per stimulus and the interval between them) on the accuracy and performance efficiency of the P300 Speller are studied. The results show that both approaches obtain similar values in terms of detection performance, obtaining around 75% F1-score for predicting a character with four series of 12 blinks per character. In addition, the region-based approach presents a more robust scheme for false predictions, maintaining a similar spelling duration. The theoretical study performed indicates that spelling a character requires around one minute.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信