平衡电网故障下双馈感应电机抽水蓄能机组控制重构策略

A. Damdoum, I. Slama-Belkhodja, M. Debbou, M. Pietrzak-David
{"title":"平衡电网故障下双馈感应电机抽水蓄能机组控制重构策略","authors":"A. Damdoum, I. Slama-Belkhodja, M. Debbou, M. Pietrzak-David","doi":"10.1109/CISTEM.2014.7076981","DOIUrl":null,"url":null,"abstract":"This paper proposes a reconfiguration scheme of a control strategy for a Doubly Fed Induction Machine based pump turbine system under balanced grid faults. The start-up and synchronization procedures are initially achieved before pump or turbine mode, with a different control at each of these three working zones. A control reconfiguration method is proposed when balanced grid faults occur during pumping mode. The reconfiguration is performed into two steps. Firstly, the control is switched from the pumping mode one to the control used for synchronization. The second step is to return to the pumping mode. The first step allows the pumping mode control parameters to be adapted to the faulty grid conditions. Study Simulations are carried out on a 4kW laboratory set-up to illustrate the effectiveness of the proposed approach.","PeriodicalId":115632,"journal":{"name":"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)","volume":"434 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Control reconfiguration strategy for Doubly Fed Induction Machine pumped storage unit under balanced grid faults\",\"authors\":\"A. Damdoum, I. Slama-Belkhodja, M. Debbou, M. Pietrzak-David\",\"doi\":\"10.1109/CISTEM.2014.7076981\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a reconfiguration scheme of a control strategy for a Doubly Fed Induction Machine based pump turbine system under balanced grid faults. The start-up and synchronization procedures are initially achieved before pump or turbine mode, with a different control at each of these three working zones. A control reconfiguration method is proposed when balanced grid faults occur during pumping mode. The reconfiguration is performed into two steps. Firstly, the control is switched from the pumping mode one to the control used for synchronization. The second step is to return to the pumping mode. The first step allows the pumping mode control parameters to be adapted to the faulty grid conditions. Study Simulations are carried out on a 4kW laboratory set-up to illustrate the effectiveness of the proposed approach.\",\"PeriodicalId\":115632,\"journal\":{\"name\":\"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)\",\"volume\":\"434 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CISTEM.2014.7076981\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Electrical Sciences and Technologies in Maghreb (CISTEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CISTEM.2014.7076981","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

针对电网平衡故障情况下的双馈感应电机泵水轮机系统,提出了一种控制策略重构方案。启动和同步程序最初是在泵或涡轮模式之前完成的,在这三个工作区域中的每一个都有不同的控制。提出了一种泵送模式下平衡电网发生故障时的控制重构方法。重新配置分为两个步骤执行。首先,控制从泵送模式切换到用于同步的控制。第二步是返回泵送模式。第一步允许泵送模式控制参数适应故障电网条件。研究模拟在一个4kW的实验室装置上进行,以说明所提出方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Control reconfiguration strategy for Doubly Fed Induction Machine pumped storage unit under balanced grid faults
This paper proposes a reconfiguration scheme of a control strategy for a Doubly Fed Induction Machine based pump turbine system under balanced grid faults. The start-up and synchronization procedures are initially achieved before pump or turbine mode, with a different control at each of these three working zones. A control reconfiguration method is proposed when balanced grid faults occur during pumping mode. The reconfiguration is performed into two steps. Firstly, the control is switched from the pumping mode one to the control used for synchronization. The second step is to return to the pumping mode. The first step allows the pumping mode control parameters to be adapted to the faulty grid conditions. Study Simulations are carried out on a 4kW laboratory set-up to illustrate the effectiveness of the proposed approach.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信