Xiaokun Niu, Xiaojuan Li, Yonghua Sun, Nian Peng, Fahui Wang
{"title":"基于M2FCA的北京市消防空间可达性测度研究","authors":"Xiaokun Niu, Xiaojuan Li, Yonghua Sun, Nian Peng, Fahui Wang","doi":"10.1109/Geoinformatics.2012.6270348","DOIUrl":null,"url":null,"abstract":"The paper presents a modified method which bases on the traditional two-step floating catchment area method and the gravitational method. the traditional two-step FCA method deals with distance and time obstruction by bisection method, any point within the threshold range have the same accessibility. Such approaches have been criticized for ignoring the differences which are caused by different distance factors. The M2FCA method addresses the internal spatial distribution problem by deriving fire area data from a smaller unit, hexagon cell. The potential cross border demand-supply interaction is taken into consideration by using circles of reasonable radius around each hexagon cell centroid as the basic spatial units, which can encompass areas on either side of an administrative border. After division of maximum threshold range which fire brigade could reach in time, the M2FCA method considers the demand point within the threshold have different access to the fire fighting service capacity during the process of fire-fighting spatial accessibility measurement study of Chengbaqu (former) Beijing city. The result shows that the improved M2FCA could reveal more detailed differences of spatial distribution in larger region, it could measure fire-fighting spatial accessibility precisely, it could accurately reveal the real fire-fighting service capacity people obtain, and predicate the areas without fire-fighting service, therefore, M2FCA could provide the basis for relevant authority to make decisions for planning and selecting sites.","PeriodicalId":259976,"journal":{"name":"2012 20th International Conference on Geoinformatics","volume":"234 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The measurement study of fire-fighting spatial accessibility in Beijing based on M2FCA\",\"authors\":\"Xiaokun Niu, Xiaojuan Li, Yonghua Sun, Nian Peng, Fahui Wang\",\"doi\":\"10.1109/Geoinformatics.2012.6270348\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents a modified method which bases on the traditional two-step floating catchment area method and the gravitational method. the traditional two-step FCA method deals with distance and time obstruction by bisection method, any point within the threshold range have the same accessibility. Such approaches have been criticized for ignoring the differences which are caused by different distance factors. The M2FCA method addresses the internal spatial distribution problem by deriving fire area data from a smaller unit, hexagon cell. The potential cross border demand-supply interaction is taken into consideration by using circles of reasonable radius around each hexagon cell centroid as the basic spatial units, which can encompass areas on either side of an administrative border. After division of maximum threshold range which fire brigade could reach in time, the M2FCA method considers the demand point within the threshold have different access to the fire fighting service capacity during the process of fire-fighting spatial accessibility measurement study of Chengbaqu (former) Beijing city. The result shows that the improved M2FCA could reveal more detailed differences of spatial distribution in larger region, it could measure fire-fighting spatial accessibility precisely, it could accurately reveal the real fire-fighting service capacity people obtain, and predicate the areas without fire-fighting service, therefore, M2FCA could provide the basis for relevant authority to make decisions for planning and selecting sites.\",\"PeriodicalId\":259976,\"journal\":{\"name\":\"2012 20th International Conference on Geoinformatics\",\"volume\":\"234 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 20th International Conference on Geoinformatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/Geoinformatics.2012.6270348\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 20th International Conference on Geoinformatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/Geoinformatics.2012.6270348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The measurement study of fire-fighting spatial accessibility in Beijing based on M2FCA
The paper presents a modified method which bases on the traditional two-step floating catchment area method and the gravitational method. the traditional two-step FCA method deals with distance and time obstruction by bisection method, any point within the threshold range have the same accessibility. Such approaches have been criticized for ignoring the differences which are caused by different distance factors. The M2FCA method addresses the internal spatial distribution problem by deriving fire area data from a smaller unit, hexagon cell. The potential cross border demand-supply interaction is taken into consideration by using circles of reasonable radius around each hexagon cell centroid as the basic spatial units, which can encompass areas on either side of an administrative border. After division of maximum threshold range which fire brigade could reach in time, the M2FCA method considers the demand point within the threshold have different access to the fire fighting service capacity during the process of fire-fighting spatial accessibility measurement study of Chengbaqu (former) Beijing city. The result shows that the improved M2FCA could reveal more detailed differences of spatial distribution in larger region, it could measure fire-fighting spatial accessibility precisely, it could accurately reveal the real fire-fighting service capacity people obtain, and predicate the areas without fire-fighting service, therefore, M2FCA could provide the basis for relevant authority to make decisions for planning and selecting sites.