两种适合线性最小二乘拟合的乳腺dce mri对比度增强非线性参数模型

A. Mehnert, M. Wildermoth, S. Crozier, E. Bengtsson, D. Kennedy
{"title":"两种适合线性最小二乘拟合的乳腺dce mri对比度增强非线性参数模型","authors":"A. Mehnert, M. Wildermoth, S. Crozier, E. Bengtsson, D. Kennedy","doi":"10.1109/DICTA.2010.108","DOIUrl":null,"url":null,"abstract":"This paper proffers two non-linear empirical parametric models—linear slope and Ricker—for use in characterising contrast enhancement in dynamic contrast enhanced (DCE) MRI. The advantage of these models over existing empirical parametric and pharmacokinetic models is that they can be fitted using linear least squares (LS). This means that fitting is quick, there is no need to specify initial parameter estimates, and there are no convergence issues. Furthermore the LS fit can itself be used to provide initial parameter estimates for a subsequent NLS fit (self-starting models). The results of an empirical evaluation of the goodness of fit (GoF) of these two models, measured in terms of both MSE and R^2, relative to a two-compartment pharmacokinetic model and the Hayton model are also presented. The GoF was evaluated using both routine clinical breast MRI data and a single high temporal resolution breast MRI data set. The results demonstrate that the linear slope model fits the routine clinical data better than any of the other models and that the two parameter self-starting Ricker model fits the data nearly as well as the three parameter Hayton model. This is also demonstrated by the results for the high temporal data and for several temporally sub-sampled versions of this data.","PeriodicalId":246460,"journal":{"name":"2010 International Conference on Digital Image Computing: Techniques and Applications","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Two Non-linear Parametric Models of Contrast Enhancement for DCE-MRI of the Breast Amenable to Fitting Using Linear Least Squares\",\"authors\":\"A. Mehnert, M. Wildermoth, S. Crozier, E. Bengtsson, D. Kennedy\",\"doi\":\"10.1109/DICTA.2010.108\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proffers two non-linear empirical parametric models—linear slope and Ricker—for use in characterising contrast enhancement in dynamic contrast enhanced (DCE) MRI. The advantage of these models over existing empirical parametric and pharmacokinetic models is that they can be fitted using linear least squares (LS). This means that fitting is quick, there is no need to specify initial parameter estimates, and there are no convergence issues. Furthermore the LS fit can itself be used to provide initial parameter estimates for a subsequent NLS fit (self-starting models). The results of an empirical evaluation of the goodness of fit (GoF) of these two models, measured in terms of both MSE and R^2, relative to a two-compartment pharmacokinetic model and the Hayton model are also presented. The GoF was evaluated using both routine clinical breast MRI data and a single high temporal resolution breast MRI data set. The results demonstrate that the linear slope model fits the routine clinical data better than any of the other models and that the two parameter self-starting Ricker model fits the data nearly as well as the three parameter Hayton model. This is also demonstrated by the results for the high temporal data and for several temporally sub-sampled versions of this data.\",\"PeriodicalId\":246460,\"journal\":{\"name\":\"2010 International Conference on Digital Image Computing: Techniques and Applications\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Digital Image Computing: Techniques and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DICTA.2010.108\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Digital Image Computing: Techniques and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DICTA.2010.108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提供了两个非线性经验参数模型-线性斜率和里克-用于表征动态对比度增强(DCE) MRI的对比度增强。与现有的经验参数模型和药代动力学模型相比,这些模型的优势在于它们可以使用线性最小二乘(LS)进行拟合。这意味着拟合是快速的,不需要指定初始参数估计,也没有收敛问题。此外,LS拟合本身可用于为后续的NLS拟合(自启动模型)提供初始参数估计。本文还介绍了两种模型相对于两室药代动力学模型和Hayton模型的拟合优度(GoF)的经验评估结果,以MSE和R^2来衡量。使用常规临床乳房MRI数据和单一高时间分辨率乳房MRI数据集评估GoF。结果表明,线性斜率模型与常规临床数据的拟合效果较好,两参数自启动Ricker模型与三参数Hayton模型的拟合效果接近。高时间数据和该数据的几个时间次采样版本的结果也证明了这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two Non-linear Parametric Models of Contrast Enhancement for DCE-MRI of the Breast Amenable to Fitting Using Linear Least Squares
This paper proffers two non-linear empirical parametric models—linear slope and Ricker—for use in characterising contrast enhancement in dynamic contrast enhanced (DCE) MRI. The advantage of these models over existing empirical parametric and pharmacokinetic models is that they can be fitted using linear least squares (LS). This means that fitting is quick, there is no need to specify initial parameter estimates, and there are no convergence issues. Furthermore the LS fit can itself be used to provide initial parameter estimates for a subsequent NLS fit (self-starting models). The results of an empirical evaluation of the goodness of fit (GoF) of these two models, measured in terms of both MSE and R^2, relative to a two-compartment pharmacokinetic model and the Hayton model are also presented. The GoF was evaluated using both routine clinical breast MRI data and a single high temporal resolution breast MRI data set. The results demonstrate that the linear slope model fits the routine clinical data better than any of the other models and that the two parameter self-starting Ricker model fits the data nearly as well as the three parameter Hayton model. This is also demonstrated by the results for the high temporal data and for several temporally sub-sampled versions of this data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信