Jarno Kukkola, Ville Pirsto, M. Routimo, M. Hinkkanen
{"title":"用三相功率变换器估计不平衡电网阻抗","authors":"Jarno Kukkola, Ville Pirsto, M. Routimo, M. Hinkkanen","doi":"10.23919/EPE20ECCEEurope43536.2020.9215676","DOIUrl":null,"url":null,"abstract":"This paper proposes a real-time method for estimating an unbalanced grid impedance using a three-phase converter. In the method, a periodic single-frequency or multi-frequency excitation signal is added to the converter voltage reference. The converter measures currents and voltages at the point of common coupling. The impedance estimate is obtained from the measurements using sliding discrete Fourier transform (SDFT). The method is experimentally validated.","PeriodicalId":241752,"journal":{"name":"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of an Unbalanced Grid Impedance Using a Three-Phase Power Converter\",\"authors\":\"Jarno Kukkola, Ville Pirsto, M. Routimo, M. Hinkkanen\",\"doi\":\"10.23919/EPE20ECCEEurope43536.2020.9215676\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a real-time method for estimating an unbalanced grid impedance using a three-phase converter. In the method, a periodic single-frequency or multi-frequency excitation signal is added to the converter voltage reference. The converter measures currents and voltages at the point of common coupling. The impedance estimate is obtained from the measurements using sliding discrete Fourier transform (SDFT). The method is experimentally validated.\",\"PeriodicalId\":241752,\"journal\":{\"name\":\"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)\",\"volume\":\"135 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/EPE20ECCEEurope43536.2020.9215676\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EPE20ECCEEurope43536.2020.9215676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Estimation of an Unbalanced Grid Impedance Using a Three-Phase Power Converter
This paper proposes a real-time method for estimating an unbalanced grid impedance using a three-phase converter. In the method, a periodic single-frequency or multi-frequency excitation signal is added to the converter voltage reference. The converter measures currents and voltages at the point of common coupling. The impedance estimate is obtained from the measurements using sliding discrete Fourier transform (SDFT). The method is experimentally validated.