通过正弦响应的自适应控制

K. Smith
{"title":"通过正弦响应的自适应控制","authors":"K. Smith","doi":"10.1109/TAC.1962.1105429","DOIUrl":null,"url":null,"abstract":"An investigation has been made in the application of sinusoidal techniques to adaptive feedback control systems. The adaptive feature of this approach is an automatic gain control. These systems contain two loops: a basic or primary control loop and an adaptive control loop. The forward-path gain of the basic loop is adjusted by the adaptive loop. A sine wave test signal is added continuously to the basic loop input and to a model. The phase shift or the amplitude of the basic loop output is measured by an adaptive computer which adjusts the forward-path gain in an attempt to hold the measured amplitude or phase-shift constant. This paper contains derivations of the adaptive loop response to changes in the process gain factor for several cases. Some of the considerations pertaining to the design of the adaptive control loop are also given.","PeriodicalId":226447,"journal":{"name":"Ire Transactions on Automatic Control","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1962-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Adaptive control through sinusoidal response\",\"authors\":\"K. Smith\",\"doi\":\"10.1109/TAC.1962.1105429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An investigation has been made in the application of sinusoidal techniques to adaptive feedback control systems. The adaptive feature of this approach is an automatic gain control. These systems contain two loops: a basic or primary control loop and an adaptive control loop. The forward-path gain of the basic loop is adjusted by the adaptive loop. A sine wave test signal is added continuously to the basic loop input and to a model. The phase shift or the amplitude of the basic loop output is measured by an adaptive computer which adjusts the forward-path gain in an attempt to hold the measured amplitude or phase-shift constant. This paper contains derivations of the adaptive loop response to changes in the process gain factor for several cases. Some of the considerations pertaining to the design of the adaptive control loop are also given.\",\"PeriodicalId\":226447,\"journal\":{\"name\":\"Ire Transactions on Automatic Control\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1962-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ire Transactions on Automatic Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAC.1962.1105429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ire Transactions on Automatic Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAC.1962.1105429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

研究了正弦技术在自适应反馈控制系统中的应用。该方法的自适应特点是自动增益控制。这些系统包含两个回路:一个基本或主控制回路和一个自适应控制回路。基本环的前向增益由自适应环调节。将正弦波测试信号连续地添加到基本环路输入和模型中。相移或基本环路输出的幅度由自适应计算机测量,该计算机调整前向增益,试图保持测量的幅度或相移恒定。本文给出了几种情况下自适应回路对过程增益因子变化的响应的推导。同时给出了有关自适应控制回路设计的一些注意事项。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Adaptive control through sinusoidal response
An investigation has been made in the application of sinusoidal techniques to adaptive feedback control systems. The adaptive feature of this approach is an automatic gain control. These systems contain two loops: a basic or primary control loop and an adaptive control loop. The forward-path gain of the basic loop is adjusted by the adaptive loop. A sine wave test signal is added continuously to the basic loop input and to a model. The phase shift or the amplitude of the basic loop output is measured by an adaptive computer which adjusts the forward-path gain in an attempt to hold the measured amplitude or phase-shift constant. This paper contains derivations of the adaptive loop response to changes in the process gain factor for several cases. Some of the considerations pertaining to the design of the adaptive control loop are also given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信