{"title":"风电高渗透输电网电压稳定性研究","authors":"Isaac Kofi Otchere, Bernard Arhin, Kwabena Amoako Kyeremeh, E. Frimpong","doi":"10.1109/PowerAfrica49420.2020.9219937","DOIUrl":null,"url":null,"abstract":"The rise of renewable energy (RE) source integration in transmission network has raised concerns on power quality. In this paper, the voltage stability of transmission networks with wind energy source integration is investigated using P-V and P-Q curves. The IEEE 30-bus system is used as a case study. The weak buses, used as possible connection points for the wind generator, were obtained using P-V curves. Graphical representation for voltage stability region for each candidate bus was also presented to help identify the best location for the wind energy source. The effect of the renewable energy source is then assessed by comparing the active power margin obtained at a specific load bus for different wind penetration levels. MATLAB software together with MATPOWER scripts were used to obtain simulated results.","PeriodicalId":325937,"journal":{"name":"2020 IEEE PES/IAS PowerAfrica","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Voltage Stability for Transmission Network with High Penetration of Wind Energy Sources\",\"authors\":\"Isaac Kofi Otchere, Bernard Arhin, Kwabena Amoako Kyeremeh, E. Frimpong\",\"doi\":\"10.1109/PowerAfrica49420.2020.9219937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The rise of renewable energy (RE) source integration in transmission network has raised concerns on power quality. In this paper, the voltage stability of transmission networks with wind energy source integration is investigated using P-V and P-Q curves. The IEEE 30-bus system is used as a case study. The weak buses, used as possible connection points for the wind generator, were obtained using P-V curves. Graphical representation for voltage stability region for each candidate bus was also presented to help identify the best location for the wind energy source. The effect of the renewable energy source is then assessed by comparing the active power margin obtained at a specific load bus for different wind penetration levels. MATLAB software together with MATPOWER scripts were used to obtain simulated results.\",\"PeriodicalId\":325937,\"journal\":{\"name\":\"2020 IEEE PES/IAS PowerAfrica\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE PES/IAS PowerAfrica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PowerAfrica49420.2020.9219937\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PES/IAS PowerAfrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PowerAfrica49420.2020.9219937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

输电网络中可再生能源并网的兴起引起了人们对电能质量的关注。本文利用P-V曲线和P-Q曲线研究了风电并网输电网的电压稳定性。本文以IEEE 30总线系统为例进行了研究。利用P-V曲线得到了作为风力发电机可能连接点的弱母线。此外,还给出了各候选母线电压稳定区域的图形表示,以帮助确定风能的最佳位置。然后通过比较在不同风透度水平下特定负载母线上获得的有功功率裕度来评估可再生能源的效果。利用MATLAB软件和MATPOWER脚本,得到仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Voltage Stability for Transmission Network with High Penetration of Wind Energy Sources
The rise of renewable energy (RE) source integration in transmission network has raised concerns on power quality. In this paper, the voltage stability of transmission networks with wind energy source integration is investigated using P-V and P-Q curves. The IEEE 30-bus system is used as a case study. The weak buses, used as possible connection points for the wind generator, were obtained using P-V curves. Graphical representation for voltage stability region for each candidate bus was also presented to help identify the best location for the wind energy source. The effect of the renewable energy source is then assessed by comparing the active power margin obtained at a specific load bus for different wind penetration levels. MATLAB software together with MATPOWER scripts were used to obtain simulated results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信