{"title":"宽温度范围上的库仑封锁测温","authors":"O. Hahtela, A. Kemppinen, J. Lehtinen, A. Manninen, E. Mykkänen, M. Prunnila, N. Yurttagül, F. Blanchet, M. Gramich, B. Karimi, E. Mannila, J. Muhojoki, J. Peltonen, J. Pekola","doi":"10.1109/CPEM49742.2020.9191726","DOIUrl":null,"url":null,"abstract":"The Coulomb Blockade Thermometer (CBT) is a primary thermometer for cryogenic temperatures, with demonstrated operation from below 1 mK up to 60 K. Its performance as a primary thermometer has been verified at temperatures from 20 mK to 200 mK at uncertainty level below 1% ($k=2$). In a new project, our aim is to extend the metrologically verified temperature range of the primary CBT up to 25 K. We also demonstrate close-to-ideal operation of a CBT with only two tunnel junctions when the device is embedded in a low-impedance environment.","PeriodicalId":373216,"journal":{"name":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","volume":"100 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Coulomb Blockade Thermometry on a Wide Temperature Range\",\"authors\":\"O. Hahtela, A. Kemppinen, J. Lehtinen, A. Manninen, E. Mykkänen, M. Prunnila, N. Yurttagül, F. Blanchet, M. Gramich, B. Karimi, E. Mannila, J. Muhojoki, J. Peltonen, J. Pekola\",\"doi\":\"10.1109/CPEM49742.2020.9191726\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Coulomb Blockade Thermometer (CBT) is a primary thermometer for cryogenic temperatures, with demonstrated operation from below 1 mK up to 60 K. Its performance as a primary thermometer has been verified at temperatures from 20 mK to 200 mK at uncertainty level below 1% ($k=2$). In a new project, our aim is to extend the metrologically verified temperature range of the primary CBT up to 25 K. We also demonstrate close-to-ideal operation of a CBT with only two tunnel junctions when the device is embedded in a low-impedance environment.\",\"PeriodicalId\":373216,\"journal\":{\"name\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"volume\":\"100 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Conference on Precision Electromagnetic Measurements (CPEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM49742.2020.9191726\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Conference on Precision Electromagnetic Measurements (CPEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM49742.2020.9191726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

库仑封锁温度计(CBT)是低温温度的主要温度计,具有从低于1 mK到60 K的演示操作。其作为主要温度计的性能已在20 mK至200 mK的温度下进行了验证,不确定度低于1% ($k=2$)。在一个新项目中,我们的目标是将主CBT的计量验证温度范围扩展到25 K。当器件嵌入低阻抗环境时,我们还演示了仅具有两个隧道结的CBT接近理想的操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coulomb Blockade Thermometry on a Wide Temperature Range
The Coulomb Blockade Thermometer (CBT) is a primary thermometer for cryogenic temperatures, with demonstrated operation from below 1 mK up to 60 K. Its performance as a primary thermometer has been verified at temperatures from 20 mK to 200 mK at uncertainty level below 1% ($k=2$). In a new project, our aim is to extend the metrologically verified temperature range of the primary CBT up to 25 K. We also demonstrate close-to-ideal operation of a CBT with only two tunnel junctions when the device is embedded in a low-impedance environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信