封闭从福尔马林输送管到垂直流鱼卵孵化器的气间隙不会降低雾化甲醛水平

J. Voorhees, Brian Fletcher, M. E. Barnes
{"title":"封闭从福尔马林输送管到垂直流鱼卵孵化器的气间隙不会降低雾化甲醛水平","authors":"J. Voorhees, Brian Fletcher, M. E. Barnes","doi":"10.4236/OJSST.2018.83006","DOIUrl":null,"url":null,"abstract":"Formalin treatments are frequently used to control water molds during hatchery incubation of salmonid eggs, creating potential occupational safety and health issues. This investigation evaluated the use of a novel technique to enclose the air gap from formalin treatment tubes to 16-tray vertical-flow incubation stacks. Standard formalin treatments of 1667 mg/L for 15-minutes were administered to one, three, or five stacks, both with, and without air gap enclosures. Enclosing the air gap did not significantly reduce aerosolized formaldehyde levels. Even during the treatment of five incubation stacks when formalin amounts were the greatest, mean (SE) peak airborne formaldehyde levels were 1.6 (0.2) mg/L and 1.5 (0.2) mg/L, either with or without air gap enclosure, respectively. The failure of air gap enclosure indicates other techniques are required to decrease aerosolized formaldehyde during formalin treatments of fish eggs in vertical-flow incubators.","PeriodicalId":183634,"journal":{"name":"Open Journal of Safety Science and Technology","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enclosing the Air Gap from Formalin Delivery Tubing to Vertical-Flow Fish Egg Incubators Does Not Decrease Aerosolized Formaldehyde Levels\",\"authors\":\"J. Voorhees, Brian Fletcher, M. E. Barnes\",\"doi\":\"10.4236/OJSST.2018.83006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Formalin treatments are frequently used to control water molds during hatchery incubation of salmonid eggs, creating potential occupational safety and health issues. This investigation evaluated the use of a novel technique to enclose the air gap from formalin treatment tubes to 16-tray vertical-flow incubation stacks. Standard formalin treatments of 1667 mg/L for 15-minutes were administered to one, three, or five stacks, both with, and without air gap enclosures. Enclosing the air gap did not significantly reduce aerosolized formaldehyde levels. Even during the treatment of five incubation stacks when formalin amounts were the greatest, mean (SE) peak airborne formaldehyde levels were 1.6 (0.2) mg/L and 1.5 (0.2) mg/L, either with or without air gap enclosure, respectively. The failure of air gap enclosure indicates other techniques are required to decrease aerosolized formaldehyde during formalin treatments of fish eggs in vertical-flow incubators.\",\"PeriodicalId\":183634,\"journal\":{\"name\":\"Open Journal of Safety Science and Technology\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Journal of Safety Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/OJSST.2018.83006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Journal of Safety Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/OJSST.2018.83006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

福尔马林处理经常用于控制水霉菌在孵化场孵化鲑鱼卵,造成潜在的职业安全和健康问题。本研究评估了将福尔马林处理管与16盘垂直流培养堆之间的气间隙封闭的新技术的使用。将1667 mg/L标准福尔马林处理15分钟,分别处理1、3或5组,有或没有气隙封闭。封闭气隙并没有显著降低雾化甲醛水平。即使在5个孵育堆处理期间,当甲醛含量最高时,空气中甲醛含量的平均(SE)峰值分别为1.6 (0.2)mg/L和1.5 (0.2)mg/L,无论是否有气隙封闭。气间隙封闭的失败表明,需要其他技术来减少垂直流孵化器中鱼卵的福尔马林处理期间的雾化甲醛。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enclosing the Air Gap from Formalin Delivery Tubing to Vertical-Flow Fish Egg Incubators Does Not Decrease Aerosolized Formaldehyde Levels
Formalin treatments are frequently used to control water molds during hatchery incubation of salmonid eggs, creating potential occupational safety and health issues. This investigation evaluated the use of a novel technique to enclose the air gap from formalin treatment tubes to 16-tray vertical-flow incubation stacks. Standard formalin treatments of 1667 mg/L for 15-minutes were administered to one, three, or five stacks, both with, and without air gap enclosures. Enclosing the air gap did not significantly reduce aerosolized formaldehyde levels. Even during the treatment of five incubation stacks when formalin amounts were the greatest, mean (SE) peak airborne formaldehyde levels were 1.6 (0.2) mg/L and 1.5 (0.2) mg/L, either with or without air gap enclosure, respectively. The failure of air gap enclosure indicates other techniques are required to decrease aerosolized formaldehyde during formalin treatments of fish eggs in vertical-flow incubators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信