{"title":"减少荧光灯/镇流器系统兼容性的不确定性","authors":"Y. Ji, R. Davis","doi":"10.1109/IAS.1996.563878","DOIUrl":null,"url":null,"abstract":"The traditional method of life testing for fluorescent lamps is to determine the median operating hours until failure for a large sample of lamps, when operated on a 3 hours on and 20 minutes off cycle. This method may take 3 years to get results. Because many new fluorescent lighting products have been introduced and many new manufacturers have entered the marketplace, the compatibility of fluorescent lamp/ballast system is of concern for manufacturers, specifiers, and end-users, who cannot wait 3 years to determine compatibility. To address this issue, some researchers have tried to develop methods to predict whether or not lamp/ballast combination will be compatible. This paper reviews different methods used to predict fluorescent lamp life, and discusses the importance of developing a reliable method for predicting fluorescent lamp/ballast compatibility. A pilot study using X-ray fluorescence is summarized, to demonstrate the potential of using this technique to better characterize the nature of the lamp/ballast system.","PeriodicalId":177291,"journal":{"name":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Reducing the uncertainty in fluorescent lamp/ballast system compatibility\",\"authors\":\"Y. Ji, R. Davis\",\"doi\":\"10.1109/IAS.1996.563878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The traditional method of life testing for fluorescent lamps is to determine the median operating hours until failure for a large sample of lamps, when operated on a 3 hours on and 20 minutes off cycle. This method may take 3 years to get results. Because many new fluorescent lighting products have been introduced and many new manufacturers have entered the marketplace, the compatibility of fluorescent lamp/ballast system is of concern for manufacturers, specifiers, and end-users, who cannot wait 3 years to determine compatibility. To address this issue, some researchers have tried to develop methods to predict whether or not lamp/ballast combination will be compatible. This paper reviews different methods used to predict fluorescent lamp life, and discusses the importance of developing a reliable method for predicting fluorescent lamp/ballast compatibility. A pilot study using X-ray fluorescence is summarized, to demonstrate the potential of using this technique to better characterize the nature of the lamp/ballast system.\",\"PeriodicalId\":177291,\"journal\":{\"name\":\"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1996.563878\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1996.563878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reducing the uncertainty in fluorescent lamp/ballast system compatibility
The traditional method of life testing for fluorescent lamps is to determine the median operating hours until failure for a large sample of lamps, when operated on a 3 hours on and 20 minutes off cycle. This method may take 3 years to get results. Because many new fluorescent lighting products have been introduced and many new manufacturers have entered the marketplace, the compatibility of fluorescent lamp/ballast system is of concern for manufacturers, specifiers, and end-users, who cannot wait 3 years to determine compatibility. To address this issue, some researchers have tried to develop methods to predict whether or not lamp/ballast combination will be compatible. This paper reviews different methods used to predict fluorescent lamp life, and discusses the importance of developing a reliable method for predicting fluorescent lamp/ballast compatibility. A pilot study using X-ray fluorescence is summarized, to demonstrate the potential of using this technique to better characterize the nature of the lamp/ballast system.