估计法国一组风力涡轮机每年闪电的平均次数

S. Pedeboy
{"title":"估计法国一组风力涡轮机每年闪电的平均次数","authors":"S. Pedeboy","doi":"10.1109/APL57308.2023.10181434","DOIUrl":null,"url":null,"abstract":"The evolution of the local lightning density observed before and after the construction of a group of wind farms installed in a mountainous region of France is analyzed using an 18-year period lightning data. Considering the effect of the limited upward lightning detection efficiency of the lightning locating system on the data, the enhancement factor is estimated to be 3.9 times the natural lightning density before the construction. This result is half the correction factor suggested by the IEC61400-24:2019 methodology, but because it is based on conservative assumptions and high-resolution lightning observations it is considered realistic. Finally, this study also brought some materials and comments on the methodology proposed in the standard guidelines.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"350 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of the average annual number of lightning flashes to a group of wind turbines in France\",\"authors\":\"S. Pedeboy\",\"doi\":\"10.1109/APL57308.2023.10181434\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The evolution of the local lightning density observed before and after the construction of a group of wind farms installed in a mountainous region of France is analyzed using an 18-year period lightning data. Considering the effect of the limited upward lightning detection efficiency of the lightning locating system on the data, the enhancement factor is estimated to be 3.9 times the natural lightning density before the construction. This result is half the correction factor suggested by the IEC61400-24:2019 methodology, but because it is based on conservative assumptions and high-resolution lightning observations it is considered realistic. Finally, this study also brought some materials and comments on the methodology proposed in the standard guidelines.\",\"PeriodicalId\":371726,\"journal\":{\"name\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"volume\":\"350 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APL57308.2023.10181434\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10181434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文利用18年雷电数据分析了法国山区一组风力发电场建设前后观测到的当地闪电密度的演变。考虑到闪电定位系统有限的向上闪电探测效率对数据的影响,估计增强系数为施工前自然闪电密度的3.9倍。这一结果是iec61400 - 24:19 19方法建议的修正系数的一半,但由于它是基于保守假设和高分辨率闪电观测,因此被认为是现实的。最后,本研究还对标准指南中提出的方法提出了一些资料和意见。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of the average annual number of lightning flashes to a group of wind turbines in France
The evolution of the local lightning density observed before and after the construction of a group of wind farms installed in a mountainous region of France is analyzed using an 18-year period lightning data. Considering the effect of the limited upward lightning detection efficiency of the lightning locating system on the data, the enhancement factor is estimated to be 3.9 times the natural lightning density before the construction. This result is half the correction factor suggested by the IEC61400-24:2019 methodology, but because it is based on conservative assumptions and high-resolution lightning observations it is considered realistic. Finally, this study also brought some materials and comments on the methodology proposed in the standard guidelines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信