利用MATLAB实时采集、处理和分析人体颈动脉脉冲波形

Sharda Vashisth, Munna Khan, R. Vijay, A. Salhan, Savita Sondhi
{"title":"利用MATLAB实时采集、处理和分析人体颈动脉脉冲波形","authors":"Sharda Vashisth, Munna Khan, R. Vijay, A. Salhan, Savita Sondhi","doi":"10.1109/NUICONE.2011.6153316","DOIUrl":null,"url":null,"abstract":"Carotid signal obtained from the patient with the help of piezoelectric sensor may be used to assess the patient's cardiac activity. Many methods based on various principles have been developed to measure the carotid pressure waveform. A piezoelectric sensor based system has been designed, developed and placed on the subject's carotid artery. The piezoelectric sensor has a transducing element adapted to sense movement due to carotid pulse and produce piezoelectric signal data in response thereto. The real time data of carotid pulse waveforms of ten human subjects in various body postures are acquired using wired as well as wireless system and filtered using MATLAB software. RR period and pulse amplitudes are quantified from the recordings by visual inspection. The technique may be used to measure and manage G stress effect on aircraft pilot.","PeriodicalId":206392,"journal":{"name":"2011 Nirma University International Conference on Engineering","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Real time acquisition, processing and analysis of human carotid pulse waveforms using MATLAB\",\"authors\":\"Sharda Vashisth, Munna Khan, R. Vijay, A. Salhan, Savita Sondhi\",\"doi\":\"10.1109/NUICONE.2011.6153316\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Carotid signal obtained from the patient with the help of piezoelectric sensor may be used to assess the patient's cardiac activity. Many methods based on various principles have been developed to measure the carotid pressure waveform. A piezoelectric sensor based system has been designed, developed and placed on the subject's carotid artery. The piezoelectric sensor has a transducing element adapted to sense movement due to carotid pulse and produce piezoelectric signal data in response thereto. The real time data of carotid pulse waveforms of ten human subjects in various body postures are acquired using wired as well as wireless system and filtered using MATLAB software. RR period and pulse amplitudes are quantified from the recordings by visual inspection. The technique may be used to measure and manage G stress effect on aircraft pilot.\",\"PeriodicalId\":206392,\"journal\":{\"name\":\"2011 Nirma University International Conference on Engineering\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Nirma University International Conference on Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NUICONE.2011.6153316\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Nirma University International Conference on Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NUICONE.2011.6153316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在压电传感器的帮助下,从患者身上获得的颈动脉信号可用于评估患者的心脏活动。基于不同原理的测量颈动脉压力波形的方法已经发展起来。一个基于压电传感器的系统已经被设计、开发并放置在受试者的颈动脉上。压电传感器具有适于感知由于颈动脉脉冲引起的运动并产生响应于该运动的压电信号数据的换能器元件。采用有线和无线系统采集10名人体受试者在不同体位下的颈动脉脉搏波形实时数据,并用MATLAB软件进行滤波。RR周期和脉冲幅度通过目视检查从记录中量化。该技术可用于飞机驾驶员G应力效应的测量和管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real time acquisition, processing and analysis of human carotid pulse waveforms using MATLAB
Carotid signal obtained from the patient with the help of piezoelectric sensor may be used to assess the patient's cardiac activity. Many methods based on various principles have been developed to measure the carotid pressure waveform. A piezoelectric sensor based system has been designed, developed and placed on the subject's carotid artery. The piezoelectric sensor has a transducing element adapted to sense movement due to carotid pulse and produce piezoelectric signal data in response thereto. The real time data of carotid pulse waveforms of ten human subjects in various body postures are acquired using wired as well as wireless system and filtered using MATLAB software. RR period and pulse amplitudes are quantified from the recordings by visual inspection. The technique may be used to measure and manage G stress effect on aircraft pilot.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信