{"title":"SNB-SLL交点及切向交点载荷面几何特性","authors":"M. Perninge, L. Soder","doi":"10.1109/ISAP.2011.6082168","DOIUrl":null,"url":null,"abstract":"Power system voltage security assessment is generally applied by considering the power system loadability surface. For a large power system, the loadability surface is a complicated hyper-surface in parameter space, and local approximations are a necessity for any analysis. Unfortunately, inequality constraints due to for example generator overexitation limiters, and higher codimension bifurcations, makes the loadability surface non-smooth. In this paper we intend to deeper investigate under which conditions the power system loadability boundary will have no visible corner at an intersection of a saddle-node bifurcation part and a switching loadability limit part of the boundary. We propose that such points are called Tangential Intersection Points.","PeriodicalId":424662,"journal":{"name":"2011 16th International Conference on Intelligent System Applications to Power Systems","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Geometric properties of the loadability surface at SNB-SLL intersections and Tangential Intersection points\",\"authors\":\"M. Perninge, L. Soder\",\"doi\":\"10.1109/ISAP.2011.6082168\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power system voltage security assessment is generally applied by considering the power system loadability surface. For a large power system, the loadability surface is a complicated hyper-surface in parameter space, and local approximations are a necessity for any analysis. Unfortunately, inequality constraints due to for example generator overexitation limiters, and higher codimension bifurcations, makes the loadability surface non-smooth. In this paper we intend to deeper investigate under which conditions the power system loadability boundary will have no visible corner at an intersection of a saddle-node bifurcation part and a switching loadability limit part of the boundary. We propose that such points are called Tangential Intersection Points.\",\"PeriodicalId\":424662,\"journal\":{\"name\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAP.2011.6082168\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 16th International Conference on Intelligent System Applications to Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP.2011.6082168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

电力系统电压安全评估一般通过考虑电力系统负荷面来实现。对于大型电力系统,负荷曲面是参数空间中一个复杂的超曲面,任何分析都需要局部逼近。不幸的是,由于诸如发电机过激励限制和更高的协维分岔等原因造成的不等式约束,使得可负荷性曲面不光滑。本文拟深入研究在何种条件下,电力系统负荷边界在鞍节点分岔部分和开关负荷极限部分的交点处没有可见的角点。我们建议把这样的点称为切交点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Geometric properties of the loadability surface at SNB-SLL intersections and Tangential Intersection points
Power system voltage security assessment is generally applied by considering the power system loadability surface. For a large power system, the loadability surface is a complicated hyper-surface in parameter space, and local approximations are a necessity for any analysis. Unfortunately, inequality constraints due to for example generator overexitation limiters, and higher codimension bifurcations, makes the loadability surface non-smooth. In this paper we intend to deeper investigate under which conditions the power system loadability boundary will have no visible corner at an intersection of a saddle-node bifurcation part and a switching loadability limit part of the boundary. We propose that such points are called Tangential Intersection Points.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信