{"title":"血糖采样方法在糖尿病数据挖掘中的影响","authors":"Diogo Machado, V. S. Costa, Pedro Brandão","doi":"10.1109/ISCC55528.2022.9912822","DOIUrl":null,"url":null,"abstract":"Finger-pricking is the traditional procedure for glycaemia monitoring. It is an invasive method where the person with diabetes is required to prick their finger. In recent years, continuous-glucose monitoring (CGM), a new and more convenient method of glycaemia monitoring, has become prevalent. CGM provides continuous access to glycaemic values without the need of finger-pricking. Data mining can be used to understand glycaemic values, and to ideally warn users of abnormal situations. CGM provides significantly more data than finger-pricking. Thus, the amount and value of CGM data ultimately questions the role of finger-pricking for glycaemic studies. In this work we use the OhioTlDM data set in order to study the importance of finger-prick-based data. We use Random Forest as a classification method, a robust method that tends to obtain quality results. Our results indicate that, although more demanding and scarcer, finger-prick-based glycaemic values have a significant role on diabetes management and on data mining.","PeriodicalId":309606,"journal":{"name":"2022 IEEE Symposium on Computers and Communications (ISCC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Impact of the glycaemic sampling method in diabetes data mining\",\"authors\":\"Diogo Machado, V. S. Costa, Pedro Brandão\",\"doi\":\"10.1109/ISCC55528.2022.9912822\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Finger-pricking is the traditional procedure for glycaemia monitoring. It is an invasive method where the person with diabetes is required to prick their finger. In recent years, continuous-glucose monitoring (CGM), a new and more convenient method of glycaemia monitoring, has become prevalent. CGM provides continuous access to glycaemic values without the need of finger-pricking. Data mining can be used to understand glycaemic values, and to ideally warn users of abnormal situations. CGM provides significantly more data than finger-pricking. Thus, the amount and value of CGM data ultimately questions the role of finger-pricking for glycaemic studies. In this work we use the OhioTlDM data set in order to study the importance of finger-prick-based data. We use Random Forest as a classification method, a robust method that tends to obtain quality results. Our results indicate that, although more demanding and scarcer, finger-prick-based glycaemic values have a significant role on diabetes management and on data mining.\",\"PeriodicalId\":309606,\"journal\":{\"name\":\"2022 IEEE Symposium on Computers and Communications (ISCC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Symposium on Computers and Communications (ISCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISCC55528.2022.9912822\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Symposium on Computers and Communications (ISCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCC55528.2022.9912822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impact of the glycaemic sampling method in diabetes data mining
Finger-pricking is the traditional procedure for glycaemia monitoring. It is an invasive method where the person with diabetes is required to prick their finger. In recent years, continuous-glucose monitoring (CGM), a new and more convenient method of glycaemia monitoring, has become prevalent. CGM provides continuous access to glycaemic values without the need of finger-pricking. Data mining can be used to understand glycaemic values, and to ideally warn users of abnormal situations. CGM provides significantly more data than finger-pricking. Thus, the amount and value of CGM data ultimately questions the role of finger-pricking for glycaemic studies. In this work we use the OhioTlDM data set in order to study the importance of finger-prick-based data. We use Random Forest as a classification method, a robust method that tends to obtain quality results. Our results indicate that, although more demanding and scarcer, finger-prick-based glycaemic values have a significant role on diabetes management and on data mining.