关于使用链式刺激获取频率特异性ABR的好处

M. Petoe, A. Bradley, W. Wilson
{"title":"关于使用链式刺激获取频率特异性ABR的好处","authors":"M. Petoe, A. Bradley, W. Wilson","doi":"10.1375/AUDI.31.2.80","DOIUrl":null,"url":null,"abstract":"To avoid the adaptation effects caused by increasing the stimulus repetition rate in frequency-specific ABR testing, some researchers have trialed alternative stimuli called 'chained stimuli'. The current study analysed the latency variance in Wave V for auditory brainstem responses evoked by representative chained stimuli (tone-pulse series stimulation with simultaneous Gliding HIghpass NOise Masker -'GHINOMA') and conventional nonchained stimuli (tone bursts) and found that these 'chained stimuli' can be used to obtain frequency-specific ABR waveforms in less time compared to conventional stimuli, without sacrificing the 'quality' of waveforms obtained. Our findings suggest that the test-retest repeatability of chained stimuli is no different than that for conventional nonchained stimuli, and that chained stimuli can be effectively substituted for conventional stimuli with no degradation in the quality of responses. The observed improvements in morphology, and the reduction in overall testing time, make the use of chained stimuli appealing in clinical practice.","PeriodicalId":114768,"journal":{"name":"Australian and New Zealand Journal of Audiology","volume":"87 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"On the benefits of using chained stimuli for frequency-specific ABR acquisition\",\"authors\":\"M. Petoe, A. Bradley, W. Wilson\",\"doi\":\"10.1375/AUDI.31.2.80\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To avoid the adaptation effects caused by increasing the stimulus repetition rate in frequency-specific ABR testing, some researchers have trialed alternative stimuli called 'chained stimuli'. The current study analysed the latency variance in Wave V for auditory brainstem responses evoked by representative chained stimuli (tone-pulse series stimulation with simultaneous Gliding HIghpass NOise Masker -'GHINOMA') and conventional nonchained stimuli (tone bursts) and found that these 'chained stimuli' can be used to obtain frequency-specific ABR waveforms in less time compared to conventional stimuli, without sacrificing the 'quality' of waveforms obtained. Our findings suggest that the test-retest repeatability of chained stimuli is no different than that for conventional nonchained stimuli, and that chained stimuli can be effectively substituted for conventional stimuli with no degradation in the quality of responses. The observed improvements in morphology, and the reduction in overall testing time, make the use of chained stimuli appealing in clinical practice.\",\"PeriodicalId\":114768,\"journal\":{\"name\":\"Australian and New Zealand Journal of Audiology\",\"volume\":\"87 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian and New Zealand Journal of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1375/AUDI.31.2.80\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian and New Zealand Journal of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1375/AUDI.31.2.80","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为了避免在频率特异性ABR测试中增加刺激重复率所引起的适应效应,一些研究人员尝试了被称为“链式刺激”的替代刺激。目前的研究分析了代表性链式刺激(同时滑动高通噪声掩体-“GHINOMA”的音脉冲系列刺激)和传统非链式刺激(音脉冲)引起的听觉脑干反应的波V潜伏期差异,发现与传统刺激相比,这些“链式刺激”可以在更短的时间内获得特定频率的ABR波形,而不会牺牲所获得波形的“质量”。结果表明,链式刺激的重测重复性与非链式刺激并无差异,链式刺激可以有效地替代传统刺激,且反应质量不会下降。观察到形态学的改善,以及总体测试时间的减少,使得链式刺激在临床实践中具有吸引力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the benefits of using chained stimuli for frequency-specific ABR acquisition
To avoid the adaptation effects caused by increasing the stimulus repetition rate in frequency-specific ABR testing, some researchers have trialed alternative stimuli called 'chained stimuli'. The current study analysed the latency variance in Wave V for auditory brainstem responses evoked by representative chained stimuli (tone-pulse series stimulation with simultaneous Gliding HIghpass NOise Masker -'GHINOMA') and conventional nonchained stimuli (tone bursts) and found that these 'chained stimuli' can be used to obtain frequency-specific ABR waveforms in less time compared to conventional stimuli, without sacrificing the 'quality' of waveforms obtained. Our findings suggest that the test-retest repeatability of chained stimuli is no different than that for conventional nonchained stimuli, and that chained stimuli can be effectively substituted for conventional stimuli with no degradation in the quality of responses. The observed improvements in morphology, and the reduction in overall testing time, make the use of chained stimuli appealing in clinical practice.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信