弱电网下VSC锁相环对直流电压稳定性的影响

P. Zhou, Xiaoming Yuan, Jiabing Hu, Yunhui Huang
{"title":"弱电网下VSC锁相环对直流电压稳定性的影响","authors":"P. Zhou, Xiaoming Yuan, Jiabing Hu, Yunhui Huang","doi":"10.1109/PESGM.2014.6939460","DOIUrl":null,"url":null,"abstract":"This paper analyzes DC-link voltage stability as affected by phase locked loop (PLL) in voltage source converters (VSC) when connected to weak grid. PLL has an impact on power transferred to the grid from VSC due to active/reactive power current regulation aligned to PLL reference frame. DC-link voltage, directly related to power flows, is then affected by PLL dynamics. Interactions between PLL and DC-link voltage control are more serious in weak grid where terminal voltage, as input of PLL, becomes susceptible to power flow variations in VSC. In this paper, a system with VSC connected to infinite bus via grid impedance is studied for operating in inverter mode. Deteriorated DC-link voltage small signal stability is presented with quick PLL response as short circuit ratio (SCR) becomes significantly low. It may be possible for PLL to improve the DC-link voltage large signal stability due to its effect on power transfer.","PeriodicalId":149134,"journal":{"name":"2014 IEEE PES General Meeting | Conference & Exposition","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"56","resultStr":"{\"title\":\"Stability of DC-link voltage as affected by phase locked loop in VSC when attached to weak grid\",\"authors\":\"P. Zhou, Xiaoming Yuan, Jiabing Hu, Yunhui Huang\",\"doi\":\"10.1109/PESGM.2014.6939460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes DC-link voltage stability as affected by phase locked loop (PLL) in voltage source converters (VSC) when connected to weak grid. PLL has an impact on power transferred to the grid from VSC due to active/reactive power current regulation aligned to PLL reference frame. DC-link voltage, directly related to power flows, is then affected by PLL dynamics. Interactions between PLL and DC-link voltage control are more serious in weak grid where terminal voltage, as input of PLL, becomes susceptible to power flow variations in VSC. In this paper, a system with VSC connected to infinite bus via grid impedance is studied for operating in inverter mode. Deteriorated DC-link voltage small signal stability is presented with quick PLL response as short circuit ratio (SCR) becomes significantly low. It may be possible for PLL to improve the DC-link voltage large signal stability due to its effect on power transfer.\",\"PeriodicalId\":149134,\"journal\":{\"name\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"56\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES General Meeting | Conference & Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2014.6939460\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES General Meeting | Conference & Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2014.6939460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 56

摘要

本文分析了电压源变换器(VSC)在接入弱电网时,锁相环对直流电压稳定性的影响。由于有功/无功电流调节与锁相环参考系一致,锁相环对从VSC传输到电网的功率有影响。直流链路电压,直接关系到功率流,然后受锁相环动力学的影响。在弱电网中,锁相环与直流电压控制之间的相互作用更为严重,终端电压作为锁相环的输入,易受VSC中潮流变化的影响。本文研究了一种通过网格阻抗与无限母线连接的VSC系统在逆变模式下的工作。直流电压小信号稳定性变差,锁相环响应变快,短路比明显降低。由于锁相环对功率传输的影响,有可能提高直流链路电压大信号的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stability of DC-link voltage as affected by phase locked loop in VSC when attached to weak grid
This paper analyzes DC-link voltage stability as affected by phase locked loop (PLL) in voltage source converters (VSC) when connected to weak grid. PLL has an impact on power transferred to the grid from VSC due to active/reactive power current regulation aligned to PLL reference frame. DC-link voltage, directly related to power flows, is then affected by PLL dynamics. Interactions between PLL and DC-link voltage control are more serious in weak grid where terminal voltage, as input of PLL, becomes susceptible to power flow variations in VSC. In this paper, a system with VSC connected to infinite bus via grid impedance is studied for operating in inverter mode. Deteriorated DC-link voltage small signal stability is presented with quick PLL response as short circuit ratio (SCR) becomes significantly low. It may be possible for PLL to improve the DC-link voltage large signal stability due to its effect on power transfer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信