入射角对装置中质子诱导单事件的影响——通过建模的关键评估

A. Akkerman, J. Barak, J. Levinson, Y. Lifshitz
{"title":"入射角对装置中质子诱导单事件的影响——通过建模的关键评估","authors":"A. Akkerman, J. Barak, J. Levinson, Y. Lifshitz","doi":"10.1109/RADECS.1997.698996","DOIUrl":null,"url":null,"abstract":"The effect of the angle of incidence on the proton induced single events in devices with finite dimensions is studied using a modified Monte Carlo model. The physical reasons for the existence or the absence of an anisotropy of the single event occurrence (with respect to the proton angle of incidence) are highlighted for the first time. Several different cases are found: (1) A significant anisotropy is predicted for devices with small lateral dimensions, a smaller sensitive layer thickness, and a large critical energy. The origin of this angular dependence is shown to be the contribution of the highly anisotropic medium mass fragments which is dominant for these conditions. (2) Published experimental data indicate only a small anisotropy in practical devices, which are characterized by a small critical deposited energy needed for SEU. It is shown that for these devices, most of the charge is created by the heavy mass fragments, which are isotropic. (3) In surface barrier detectors (SBDs) which have large lateral dimensions the effect of the isotropic light mass fragments takes over and the anisotropy for proton events is small even for large critical energies and a small sensitive layer thickness. The conclusion of the present work is that the single event rate in space can be evaluated by the normal incidence cross sections for all devices which have a significant sensitivity for proton induced events.","PeriodicalId":106774,"journal":{"name":"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"The effect of the angle of incidence on proton induced single events in devices-a critical assessment by modeling\",\"authors\":\"A. Akkerman, J. Barak, J. Levinson, Y. Lifshitz\",\"doi\":\"10.1109/RADECS.1997.698996\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of the angle of incidence on the proton induced single events in devices with finite dimensions is studied using a modified Monte Carlo model. The physical reasons for the existence or the absence of an anisotropy of the single event occurrence (with respect to the proton angle of incidence) are highlighted for the first time. Several different cases are found: (1) A significant anisotropy is predicted for devices with small lateral dimensions, a smaller sensitive layer thickness, and a large critical energy. The origin of this angular dependence is shown to be the contribution of the highly anisotropic medium mass fragments which is dominant for these conditions. (2) Published experimental data indicate only a small anisotropy in practical devices, which are characterized by a small critical deposited energy needed for SEU. It is shown that for these devices, most of the charge is created by the heavy mass fragments, which are isotropic. (3) In surface barrier detectors (SBDs) which have large lateral dimensions the effect of the isotropic light mass fragments takes over and the anisotropy for proton events is small even for large critical energies and a small sensitive layer thickness. The conclusion of the present work is that the single event rate in space can be evaluated by the normal incidence cross sections for all devices which have a significant sensitivity for proton induced events.\",\"PeriodicalId\":106774,\"journal\":{\"name\":\"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADECS.1997.698996\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"RADECS 97. Fourth European Conference on Radiation and its Effects on Components and Systems (Cat. No.97TH8294)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADECS.1997.698996","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

用改进的蒙特卡罗模型研究了有限维器件中入射角对质子诱导单事件的影响。单事件发生的各向异性(相对于质子入射角)存在或不存在的物理原因首次被强调。发现了几种不同的情况:(1)对于横向尺寸小、敏感层厚度小和临界能量大的器件,预测了显著的各向异性。这种角度依赖性的起源被证明是高度各向异性的介质质量碎片的贡献,这在这些条件下占主导地位。(2)已发表的实验数据表明,实际器件的各向异性很小,其特征是SEU所需的临界沉积能量很小。结果表明,对于这些装置,大部分电荷是由各向同性的大质量碎片产生的。(3)在横向尺寸较大的表面势垒探测器(sds)中,各向同性光质量碎片的影响起主导作用,即使在较大的临界能量和较小的敏感层厚度下,质子事件的各向异性也较小。本工作的结论是,空间中的单事件率可以通过对质子诱导事件具有显著敏感性的所有装置的正入射截面来评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of the angle of incidence on proton induced single events in devices-a critical assessment by modeling
The effect of the angle of incidence on the proton induced single events in devices with finite dimensions is studied using a modified Monte Carlo model. The physical reasons for the existence or the absence of an anisotropy of the single event occurrence (with respect to the proton angle of incidence) are highlighted for the first time. Several different cases are found: (1) A significant anisotropy is predicted for devices with small lateral dimensions, a smaller sensitive layer thickness, and a large critical energy. The origin of this angular dependence is shown to be the contribution of the highly anisotropic medium mass fragments which is dominant for these conditions. (2) Published experimental data indicate only a small anisotropy in practical devices, which are characterized by a small critical deposited energy needed for SEU. It is shown that for these devices, most of the charge is created by the heavy mass fragments, which are isotropic. (3) In surface barrier detectors (SBDs) which have large lateral dimensions the effect of the isotropic light mass fragments takes over and the anisotropy for proton events is small even for large critical energies and a small sensitive layer thickness. The conclusion of the present work is that the single event rate in space can be evaluated by the normal incidence cross sections for all devices which have a significant sensitivity for proton induced events.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信