G. Barbosa, G. Dantas, Bianca Silva, S. M. Pinheiro, H. Santos, W. H. Vieira
{"title":"膝关节主动伸展运动范围的器械内和器械间可靠性","authors":"G. Barbosa, G. Dantas, Bianca Silva, S. M. Pinheiro, H. Santos, W. H. Vieira","doi":"10.1590/S1980-6574201700010008","DOIUrl":null,"url":null,"abstract":"The objective of the present study was to evaluate the reliability of intra-rater and inter-instrument measures during two flexibility programs. Fifty-three active and healthy males, aged between 18 and 28 years old, were randomly included in three groups: control (Cg, n = 18), static stretching (SSg, n = 17), and dynamic stretching (DSg, n = 18). All participants underwent measurements of their active range of knee extension using manual goniometry and computerized photogrammetry, measured in four separated assessments and analyzed using the SPSS, with ((5%. Both methodologies presented very strongintra-raterreliability (ICC: 0.91(0.99; P<0.001) at all four assessments in all the groups, and the instruments showed weak (r: 0.31-0.6) to strong(r: 0.61-0.9) correlation, in the Cg (P<0.05) and strong (r: 0.61-0.9) in the SSg and DSg (P<0.01), although without differences between groups, indicating that the measures are equally reliable, regardless of interventions.","PeriodicalId":267352,"journal":{"name":"Motriz-revista De Educacao Fisica","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Intra-rater and Inter-instrument Reliability on Range of Movement of Active Knee Extension\",\"authors\":\"G. Barbosa, G. Dantas, Bianca Silva, S. M. Pinheiro, H. Santos, W. H. Vieira\",\"doi\":\"10.1590/S1980-6574201700010008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of the present study was to evaluate the reliability of intra-rater and inter-instrument measures during two flexibility programs. Fifty-three active and healthy males, aged between 18 and 28 years old, were randomly included in three groups: control (Cg, n = 18), static stretching (SSg, n = 17), and dynamic stretching (DSg, n = 18). All participants underwent measurements of their active range of knee extension using manual goniometry and computerized photogrammetry, measured in four separated assessments and analyzed using the SPSS, with ((5%. Both methodologies presented very strongintra-raterreliability (ICC: 0.91(0.99; P<0.001) at all four assessments in all the groups, and the instruments showed weak (r: 0.31-0.6) to strong(r: 0.61-0.9) correlation, in the Cg (P<0.05) and strong (r: 0.61-0.9) in the SSg and DSg (P<0.01), although without differences between groups, indicating that the measures are equally reliable, regardless of interventions.\",\"PeriodicalId\":267352,\"journal\":{\"name\":\"Motriz-revista De Educacao Fisica\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Motriz-revista De Educacao Fisica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S1980-6574201700010008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Motriz-revista De Educacao Fisica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1980-6574201700010008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
摘要
本研究的目的是评估两种灵活性方案中仪器内和仪器间测量的可靠性。53名年龄在18 ~ 28岁的健康活跃男性随机分为3组:对照组(Cg, n = 18)、静态拉伸组(SSg, n = 17)和动态拉伸组(DSg, n = 18)。所有参与者都使用人工角度测量法和计算机摄影测量法测量了他们的膝关节伸展活动范围,在四个独立的评估中测量,并使用SPSS进行分析,误差为(5%)。两种方法均表现出很强的评级内信度(ICC: 0.91;P<0.001),并且这些工具在Cg中显示弱(r: 0.31-0.6)到强(r: 0.61-0.9)相关性(P<0.05),在SSg和DSg中显示强(r: 0.61-0.9)相关性(P<0.01),尽管组间没有差异,表明这些测量方法同样可靠,无论干预措施如何。
Intra-rater and Inter-instrument Reliability on Range of Movement of Active Knee Extension
The objective of the present study was to evaluate the reliability of intra-rater and inter-instrument measures during two flexibility programs. Fifty-three active and healthy males, aged between 18 and 28 years old, were randomly included in three groups: control (Cg, n = 18), static stretching (SSg, n = 17), and dynamic stretching (DSg, n = 18). All participants underwent measurements of their active range of knee extension using manual goniometry and computerized photogrammetry, measured in four separated assessments and analyzed using the SPSS, with ((5%. Both methodologies presented very strongintra-raterreliability (ICC: 0.91(0.99; P<0.001) at all four assessments in all the groups, and the instruments showed weak (r: 0.31-0.6) to strong(r: 0.61-0.9) correlation, in the Cg (P<0.05) and strong (r: 0.61-0.9) in the SSg and DSg (P<0.01), although without differences between groups, indicating that the measures are equally reliable, regardless of interventions.