G. Naishadham, E. Bekyarova, Yuchen Qian, K. Naishadham
{"title":"用于呼吸系统健康的低频阻抗测量传感器设计","authors":"G. Naishadham, E. Bekyarova, Yuchen Qian, K. Naishadham","doi":"10.1109/ICSENS.2018.8589787","DOIUrl":null,"url":null,"abstract":"Real-time monitoring of environmental exposure causing chronic diseases including asthma and COPD has assumed enormous significance due to prolific advances in materials science and electronics. Such monitoring demands low-power electronic devices for signal conditioning and measurement to be integrated with state-of-the-art environmental sensors. Ozone is a known trigger of asthma causing significant health burden worldwide. In this paper, sensitive detectors based on functionalized (i.e. high specificity) single-walled carbon nanotubes are designed to measure ambient ozone exposure. The electronic interface comprises low-power integration of the chemical sensor with a commercial device to measure the complex (sensor) impedance at a frequency between 40 kHz and 1 MHz. Simultaneous measurement of magnitude and phase on several ozone sensors reveal response change of 35% in the former and 80% in the latter, and a detection limit of only 10 ppb. This innovative chip-based impedance measurement technique has the potential for characterizing the personal exposure to ambient air pollution triggers of respiratory diseases.","PeriodicalId":405874,"journal":{"name":"2018 IEEE SENSORS","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Design of Low-Frequency Impedance Measurement Sensors for Respiratory Health\",\"authors\":\"G. Naishadham, E. Bekyarova, Yuchen Qian, K. Naishadham\",\"doi\":\"10.1109/ICSENS.2018.8589787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Real-time monitoring of environmental exposure causing chronic diseases including asthma and COPD has assumed enormous significance due to prolific advances in materials science and electronics. Such monitoring demands low-power electronic devices for signal conditioning and measurement to be integrated with state-of-the-art environmental sensors. Ozone is a known trigger of asthma causing significant health burden worldwide. In this paper, sensitive detectors based on functionalized (i.e. high specificity) single-walled carbon nanotubes are designed to measure ambient ozone exposure. The electronic interface comprises low-power integration of the chemical sensor with a commercial device to measure the complex (sensor) impedance at a frequency between 40 kHz and 1 MHz. Simultaneous measurement of magnitude and phase on several ozone sensors reveal response change of 35% in the former and 80% in the latter, and a detection limit of only 10 ppb. This innovative chip-based impedance measurement technique has the potential for characterizing the personal exposure to ambient air pollution triggers of respiratory diseases.\",\"PeriodicalId\":405874,\"journal\":{\"name\":\"2018 IEEE SENSORS\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2018.8589787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2018.8589787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of Low-Frequency Impedance Measurement Sensors for Respiratory Health
Real-time monitoring of environmental exposure causing chronic diseases including asthma and COPD has assumed enormous significance due to prolific advances in materials science and electronics. Such monitoring demands low-power electronic devices for signal conditioning and measurement to be integrated with state-of-the-art environmental sensors. Ozone is a known trigger of asthma causing significant health burden worldwide. In this paper, sensitive detectors based on functionalized (i.e. high specificity) single-walled carbon nanotubes are designed to measure ambient ozone exposure. The electronic interface comprises low-power integration of the chemical sensor with a commercial device to measure the complex (sensor) impedance at a frequency between 40 kHz and 1 MHz. Simultaneous measurement of magnitude and phase on several ozone sensors reveal response change of 35% in the former and 80% in the latter, and a detection limit of only 10 ppb. This innovative chip-based impedance measurement technique has the potential for characterizing the personal exposure to ambient air pollution triggers of respiratory diseases.