研究三次谐波引起的中性点对地电压升高对配电系统的影响

A. Maitra, W. Sunderman, D. Dorr
{"title":"研究三次谐波引起的中性点对地电压升高对配电系统的影响","authors":"A. Maitra, W. Sunderman, D. Dorr","doi":"10.1109/PES.2006.1709636","DOIUrl":null,"url":null,"abstract":"Neutral-earth voltages have been a topic of investigation and research for many generations. Non-linear loads, and the harmonics that they generate have also been a topic of research in more recent years. An unexpected side effect of distributed nonlinear loads is an increase in neutral-earth voltages on distribution systems. A case study was presented that shows a correlation between high levels of zero sequence triplen (especially the 3rd) harmonics in distribution systems and an increase in neutral-earth voltages. A method of modeling distribution systems with distributed nonlinear loads was presented. These models were based upon circuit configurations, conductor data, grounding information, transformer data, and any previous measurement data gathered from the field. Additionally, some means for reducing neutral-earth voltages were presented","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Studying the impact of elevated neutral to earth voltage on distribution systems due to triplen harmonics\",\"authors\":\"A. Maitra, W. Sunderman, D. Dorr\",\"doi\":\"10.1109/PES.2006.1709636\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neutral-earth voltages have been a topic of investigation and research for many generations. Non-linear loads, and the harmonics that they generate have also been a topic of research in more recent years. An unexpected side effect of distributed nonlinear loads is an increase in neutral-earth voltages on distribution systems. A case study was presented that shows a correlation between high levels of zero sequence triplen (especially the 3rd) harmonics in distribution systems and an increase in neutral-earth voltages. A method of modeling distribution systems with distributed nonlinear loads was presented. These models were based upon circuit configurations, conductor data, grounding information, transformer data, and any previous measurement data gathered from the field. Additionally, some means for reducing neutral-earth voltages were presented\",\"PeriodicalId\":267582,\"journal\":{\"name\":\"2006 IEEE Power Engineering Society General Meeting\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2006.1709636\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709636","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

中性点电压一直是许多代人调查和研究的课题。非线性负载及其产生的谐波也是近年来研究的一个课题。分布式非线性负荷的一个意想不到的副作用是配电系统中接地电压的增加。通过实例分析,揭示了配电系统中高电平的零序三次谐波(特别是三次谐波)与中性点电压升高之间的关系。提出了一种具有分布式非线性负荷的配电系统建模方法。这些模型是基于电路配置、导体数据、接地信息、变压器数据和以前从现场收集的任何测量数据。此外,还提出了一些降低中接地电压的方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Studying the impact of elevated neutral to earth voltage on distribution systems due to triplen harmonics
Neutral-earth voltages have been a topic of investigation and research for many generations. Non-linear loads, and the harmonics that they generate have also been a topic of research in more recent years. An unexpected side effect of distributed nonlinear loads is an increase in neutral-earth voltages on distribution systems. A case study was presented that shows a correlation between high levels of zero sequence triplen (especially the 3rd) harmonics in distribution systems and an increase in neutral-earth voltages. A method of modeling distribution systems with distributed nonlinear loads was presented. These models were based upon circuit configurations, conductor data, grounding information, transformer data, and any previous measurement data gathered from the field. Additionally, some means for reducing neutral-earth voltages were presented
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信