三天线极化技术在极低交叉极化测量中的改进

A. Newell, D. Gentle, P. Vizcaino, Z. Tian
{"title":"三天线极化技术在极低交叉极化测量中的改进","authors":"A. Newell, D. Gentle, P. Vizcaino, Z. Tian","doi":"10.23919/AMTAP.2019.8906327","DOIUrl":null,"url":null,"abstract":"The Three-antenna polarization measurement technique is used to determine the axial ratio, tilt angle and sense of polarization of three antennas from measurements on each of three antenna pairs. The three antennas are generally nominally linearly polarized and the measurement data consists of the change in amplitude from the initial antenna orientation where they are co-polarized to the orientation where one of the antennas is rotated about its axis to the null amplitude position. The sign of the phase change is also noted and the phase change at the null position is known from theoretical calculations to be either plus or minus 90 degrees. The correct sign is determined from the sign of the phase change. For antennas with axial ratios in the range of 50 to 80 dB that will be used as near-field probes or as feeds for reflector antennas, it is imperative to measure the polarization parameters as accurately as possible. The primary source of uncertainty in the measurement is due to scattered signals in the measurement range that arise from multiple reflections between the two antennas and from the absorber on the chamber walls. For antennas with very large axial ratios, the scattered signals can be larger than the true measurement signal. These scattered signals can change the sign of the phase and produce large errors in the amplitude at the null. If the separation distance between the antennas is adjusted after rotating to the null to produce a maximum amplitude, the scattered signal is in phase with the true measurement signal. If the distance is adjusted for the minimum at the null, the scattered and true signals are out of phase. Measurements at these two positions will produce the best measurement of the phase sign and the true amplitude. But if measurements are being performed at a number of frequencies, the maximum and minimum amplitude positions will be different for each frequency, and this will complicate automated multifrequency measurements. New improvements have been developed in the details of the measurements that greatly improve the determination of the phase sign and the amplitude at the null for multiple frequency measurements and these will be described and illustrated in the following paper. With these improvements, the estimated uncertainty of a 60 dB axial ratio is on the order of 1.8 dB. A new technique has also been developed to improve the source correction of the pattern data for probes with large axial ratios that guarantees that the on-axis polarization of the pattern data will be identical to the results of the Three-antenna measurement. The probe correction processing will then produce the highest accuracy results for the polarization of the AUT.","PeriodicalId":339768,"journal":{"name":"2019 Antenna Measurement Techniques Association Symposium (AMTA)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Improvements in the Measurement of Very Low Cross Polarization Using the Three Antenna Polarization Technique\",\"authors\":\"A. Newell, D. Gentle, P. Vizcaino, Z. Tian\",\"doi\":\"10.23919/AMTAP.2019.8906327\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Three-antenna polarization measurement technique is used to determine the axial ratio, tilt angle and sense of polarization of three antennas from measurements on each of three antenna pairs. The three antennas are generally nominally linearly polarized and the measurement data consists of the change in amplitude from the initial antenna orientation where they are co-polarized to the orientation where one of the antennas is rotated about its axis to the null amplitude position. The sign of the phase change is also noted and the phase change at the null position is known from theoretical calculations to be either plus or minus 90 degrees. The correct sign is determined from the sign of the phase change. For antennas with axial ratios in the range of 50 to 80 dB that will be used as near-field probes or as feeds for reflector antennas, it is imperative to measure the polarization parameters as accurately as possible. The primary source of uncertainty in the measurement is due to scattered signals in the measurement range that arise from multiple reflections between the two antennas and from the absorber on the chamber walls. For antennas with very large axial ratios, the scattered signals can be larger than the true measurement signal. These scattered signals can change the sign of the phase and produce large errors in the amplitude at the null. If the separation distance between the antennas is adjusted after rotating to the null to produce a maximum amplitude, the scattered signal is in phase with the true measurement signal. If the distance is adjusted for the minimum at the null, the scattered and true signals are out of phase. Measurements at these two positions will produce the best measurement of the phase sign and the true amplitude. But if measurements are being performed at a number of frequencies, the maximum and minimum amplitude positions will be different for each frequency, and this will complicate automated multifrequency measurements. New improvements have been developed in the details of the measurements that greatly improve the determination of the phase sign and the amplitude at the null for multiple frequency measurements and these will be described and illustrated in the following paper. With these improvements, the estimated uncertainty of a 60 dB axial ratio is on the order of 1.8 dB. A new technique has also been developed to improve the source correction of the pattern data for probes with large axial ratios that guarantees that the on-axis polarization of the pattern data will be identical to the results of the Three-antenna measurement. The probe correction processing will then produce the highest accuracy results for the polarization of the AUT.\",\"PeriodicalId\":339768,\"journal\":{\"name\":\"2019 Antenna Measurement Techniques Association Symposium (AMTA)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Antenna Measurement Techniques Association Symposium (AMTA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/AMTAP.2019.8906327\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Antenna Measurement Techniques Association Symposium (AMTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AMTAP.2019.8906327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

三天线极化测量技术是通过对三对天线的测量来确定三天线的轴比、倾斜角和极化感。三个天线通常名义上是线极化的,测量数据包括从它们共极化的初始天线方向到其中一个天线绕其轴旋转到零振幅位置的方向的幅度变化。相位变化的符号也被注意到,零点位置的相位变化从理论计算中已知为正或负90度。正确的符号是由相变的符号确定的。对于轴向比在50 ~ 80db范围内的天线,作为近场探头或反射天线的馈源,必须尽可能准确地测量极化参数。测量不确定度的主要来源是由于测量范围内的散射信号,这些信号是由两个天线之间的多次反射和腔室壁上的吸收器产生的。对于轴比非常大的天线,散射信号可能大于真实测量信号。这些散射信号可以改变相位的符号,并在零点处产生较大的幅度误差。如果旋转到零后调整天线之间的分离距离,产生最大幅度,则散射信号与真实测量信号同相。如果在零点处将距离调整为最小值,则散射信号和真信号将不相符合。在这两个位置测量将产生相位符号和真实幅度的最佳测量结果。但是,如果在多个频率下进行测量,则每个频率的最大和最小幅度位置将不同,这将使自动化多频率测量复杂化。在测量的细节方面已经有了新的改进,这些改进大大提高了对多频率测量的相位符号和零点幅度的确定,这些将在下面的文章中进行描述和说明。通过这些改进,60 dB轴比的估计不确定度约为1.8 dB。对于具有大轴向比的探针,还开发了一种新的技术来改善方向图数据的源校正,以保证方向图数据的轴上极化与三天线测量结果相同。然后,探头校正处理将产生AUT极化的最高精度结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvements in the Measurement of Very Low Cross Polarization Using the Three Antenna Polarization Technique
The Three-antenna polarization measurement technique is used to determine the axial ratio, tilt angle and sense of polarization of three antennas from measurements on each of three antenna pairs. The three antennas are generally nominally linearly polarized and the measurement data consists of the change in amplitude from the initial antenna orientation where they are co-polarized to the orientation where one of the antennas is rotated about its axis to the null amplitude position. The sign of the phase change is also noted and the phase change at the null position is known from theoretical calculations to be either plus or minus 90 degrees. The correct sign is determined from the sign of the phase change. For antennas with axial ratios in the range of 50 to 80 dB that will be used as near-field probes or as feeds for reflector antennas, it is imperative to measure the polarization parameters as accurately as possible. The primary source of uncertainty in the measurement is due to scattered signals in the measurement range that arise from multiple reflections between the two antennas and from the absorber on the chamber walls. For antennas with very large axial ratios, the scattered signals can be larger than the true measurement signal. These scattered signals can change the sign of the phase and produce large errors in the amplitude at the null. If the separation distance between the antennas is adjusted after rotating to the null to produce a maximum amplitude, the scattered signal is in phase with the true measurement signal. If the distance is adjusted for the minimum at the null, the scattered and true signals are out of phase. Measurements at these two positions will produce the best measurement of the phase sign and the true amplitude. But if measurements are being performed at a number of frequencies, the maximum and minimum amplitude positions will be different for each frequency, and this will complicate automated multifrequency measurements. New improvements have been developed in the details of the measurements that greatly improve the determination of the phase sign and the amplitude at the null for multiple frequency measurements and these will be described and illustrated in the following paper. With these improvements, the estimated uncertainty of a 60 dB axial ratio is on the order of 1.8 dB. A new technique has also been developed to improve the source correction of the pattern data for probes with large axial ratios that guarantees that the on-axis polarization of the pattern data will be identical to the results of the Three-antenna measurement. The probe correction processing will then produce the highest accuracy results for the polarization of the AUT.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信