{"title":"IEC 61850中使用GOOSE和SMV时间关键消息的变电站通信仿真模型","authors":"Hector Leon, C. Montez, M. Stemmer, F. Vasques","doi":"10.1109/WFCS.2016.7496500","DOIUrl":null,"url":null,"abstract":"IEC 61850 is a communication standard for electrical Substation Automation Systems (SAS). It defines both the information model and services used for communication between Intelligent Electronic Devices (IEDs) in a substation. The adoption of this standard brings several advantages for the design and operation of substations. The abstract data models defined in IEC 61850 can be mapped upon application protocols, such as MMS, GOOSE or SMV. These protocols can run upon TCP/IP networks or upon specific high speed Ethernet LANs, in order to match the timing requirements associated to protective relaying mechanisms. For the specific case of GOOSE messages, the standard specifies the use of VLANs (Virtual LANs) with priority tagging (IEEE 802.1q) to implement separate virtual networks with the appropriate message priority levels, in order to ensure the specified response times. The lack of adequate simulation models that enable the response time assessment of both SMV and GOOSE messages is one of the shortcomings of available simulation tools. In this paper, we propose simulation models for the IEC 61850 communication standard, targeting application that use GOOSE and SMV messages. This simulation models has been built upon OMNeT++/INET. The simulation results obtained from a typical IEC 61850 communication scenario show the effectiveness of the developed models. Some of these results have been experimentally validated.","PeriodicalId":413770,"journal":{"name":"2016 IEEE World Conference on Factory Communication Systems (WFCS)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Simulation models for IEC 61850 communication in electrical substations using GOOSE and SMV time-critical messages\",\"authors\":\"Hector Leon, C. Montez, M. Stemmer, F. Vasques\",\"doi\":\"10.1109/WFCS.2016.7496500\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IEC 61850 is a communication standard for electrical Substation Automation Systems (SAS). It defines both the information model and services used for communication between Intelligent Electronic Devices (IEDs) in a substation. The adoption of this standard brings several advantages for the design and operation of substations. The abstract data models defined in IEC 61850 can be mapped upon application protocols, such as MMS, GOOSE or SMV. These protocols can run upon TCP/IP networks or upon specific high speed Ethernet LANs, in order to match the timing requirements associated to protective relaying mechanisms. For the specific case of GOOSE messages, the standard specifies the use of VLANs (Virtual LANs) with priority tagging (IEEE 802.1q) to implement separate virtual networks with the appropriate message priority levels, in order to ensure the specified response times. The lack of adequate simulation models that enable the response time assessment of both SMV and GOOSE messages is one of the shortcomings of available simulation tools. In this paper, we propose simulation models for the IEC 61850 communication standard, targeting application that use GOOSE and SMV messages. This simulation models has been built upon OMNeT++/INET. The simulation results obtained from a typical IEC 61850 communication scenario show the effectiveness of the developed models. Some of these results have been experimentally validated.\",\"PeriodicalId\":413770,\"journal\":{\"name\":\"2016 IEEE World Conference on Factory Communication Systems (WFCS)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE World Conference on Factory Communication Systems (WFCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WFCS.2016.7496500\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE World Conference on Factory Communication Systems (WFCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WFCS.2016.7496500","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simulation models for IEC 61850 communication in electrical substations using GOOSE and SMV time-critical messages
IEC 61850 is a communication standard for electrical Substation Automation Systems (SAS). It defines both the information model and services used for communication between Intelligent Electronic Devices (IEDs) in a substation. The adoption of this standard brings several advantages for the design and operation of substations. The abstract data models defined in IEC 61850 can be mapped upon application protocols, such as MMS, GOOSE or SMV. These protocols can run upon TCP/IP networks or upon specific high speed Ethernet LANs, in order to match the timing requirements associated to protective relaying mechanisms. For the specific case of GOOSE messages, the standard specifies the use of VLANs (Virtual LANs) with priority tagging (IEEE 802.1q) to implement separate virtual networks with the appropriate message priority levels, in order to ensure the specified response times. The lack of adequate simulation models that enable the response time assessment of both SMV and GOOSE messages is one of the shortcomings of available simulation tools. In this paper, we propose simulation models for the IEC 61850 communication standard, targeting application that use GOOSE and SMV messages. This simulation models has been built upon OMNeT++/INET. The simulation results obtained from a typical IEC 61850 communication scenario show the effectiveness of the developed models. Some of these results have been experimentally validated.