混响室时间常数的测量及曲线拟合技术

Xiaotian Zhang, M. Robinson, I. Flintoft
{"title":"混响室时间常数的测量及曲线拟合技术","authors":"Xiaotian Zhang, M. Robinson, I. Flintoft","doi":"10.1109/ISEMC.2015.7256196","DOIUrl":null,"url":null,"abstract":"The reverberation chamber time constant quantifies how fast a reverberation chamber loses its stored energy at different frequencies, which makes it a very important parameter in many power related tests, such as the measurement of antenna efficiency, the measurement of absorption cross section, and the electromagnetic immunity test of electronic devices. The chamber time constant is usually obtained by doing regressions of power delay profile and calculating its gradient. But the shape of power delay profile can sometimes be distorted by the band limited window function applied in the frequency domain. A non-linear curve fitting technique which can cancel the effect of window function was developed, aiming to give a robust determination of the chamber time constant. With the help of this technique, window functions with much smaller bandwidth can be applied without introducing error in the evaluation of chamber time constant. In this paper, a 1 MHz wide window function in which only 10 samples of S21 are available was put under test and it was found a robust answer of chamber time constant can still be given by non-linear curve fitting techniques. Therefore the measurement time can be reduced and the frequency resolution of the chamber time constant can be increased at the same time.","PeriodicalId":412708,"journal":{"name":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"On measurement of reverberation chamber time constant and related curve fitting techniques\",\"authors\":\"Xiaotian Zhang, M. Robinson, I. Flintoft\",\"doi\":\"10.1109/ISEMC.2015.7256196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reverberation chamber time constant quantifies how fast a reverberation chamber loses its stored energy at different frequencies, which makes it a very important parameter in many power related tests, such as the measurement of antenna efficiency, the measurement of absorption cross section, and the electromagnetic immunity test of electronic devices. The chamber time constant is usually obtained by doing regressions of power delay profile and calculating its gradient. But the shape of power delay profile can sometimes be distorted by the band limited window function applied in the frequency domain. A non-linear curve fitting technique which can cancel the effect of window function was developed, aiming to give a robust determination of the chamber time constant. With the help of this technique, window functions with much smaller bandwidth can be applied without introducing error in the evaluation of chamber time constant. In this paper, a 1 MHz wide window function in which only 10 samples of S21 are available was put under test and it was found a robust answer of chamber time constant can still be given by non-linear curve fitting techniques. Therefore the measurement time can be reduced and the frequency resolution of the chamber time constant can be increased at the same time.\",\"PeriodicalId\":412708,\"journal\":{\"name\":\"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2015.7256196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2015.7256196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

混响室时间常数量化了混响室在不同频率下储存能量的损耗速度,在天线效率测量、吸收截面测量、电子设备电磁抗扰度测试等功率相关测试中是一个非常重要的参数。腔室时间常数通常是通过对功率延迟曲线进行回归并计算其梯度来获得的。但是,在频域应用带限窗函数有时会使功率延迟曲线的形状发生畸变。提出了一种能够消除窗函数影响的非线性曲线拟合方法,旨在对腔室时间常数进行鲁棒性测定。在此技术的帮助下,可以应用更小带宽的窗函数,而不会在腔室时间常数的计算中引入误差。本文对1 MHz宽窗函数进行了测试,其中只有10个S21样本,发现非线性曲线拟合技术仍然可以给出腔室时间常数的鲁棒答案。因此,可以缩短测量时间,同时提高腔室时间常数的频率分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On measurement of reverberation chamber time constant and related curve fitting techniques
The reverberation chamber time constant quantifies how fast a reverberation chamber loses its stored energy at different frequencies, which makes it a very important parameter in many power related tests, such as the measurement of antenna efficiency, the measurement of absorption cross section, and the electromagnetic immunity test of electronic devices. The chamber time constant is usually obtained by doing regressions of power delay profile and calculating its gradient. But the shape of power delay profile can sometimes be distorted by the band limited window function applied in the frequency domain. A non-linear curve fitting technique which can cancel the effect of window function was developed, aiming to give a robust determination of the chamber time constant. With the help of this technique, window functions with much smaller bandwidth can be applied without introducing error in the evaluation of chamber time constant. In this paper, a 1 MHz wide window function in which only 10 samples of S21 are available was put under test and it was found a robust answer of chamber time constant can still be given by non-linear curve fitting techniques. Therefore the measurement time can be reduced and the frequency resolution of the chamber time constant can be increased at the same time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信