Li Wang, Che-Hao Chang, Cheng-Tai Wu, A. Prokhorov
{"title":"与大型海上风电场连接的简化台湾电力系统稳定性评估","authors":"Li Wang, Che-Hao Chang, Cheng-Tai Wu, A. Prokhorov","doi":"10.1109/IFEEC.2015.7361389","DOIUrl":null,"url":null,"abstract":"This paper presents the small-signal stability analysis results of the simplified Taiwan Power System connected with a high-capacity wind farm of 46 MW. The q-d axis equivalent-circuit model is employed to establish the complete system model of simplified Taiwan Power System connected with the wind farm under three-phase balanced loading conditions. The eigenvalue results at the specific operating point and the time-domain simulations of the studied integrated power system under a three-phase short-circuit fault are both performed. From the eigenvalues and time-domain results, it shows that the simplified Taiwan Power System connected with the high-capacity wind farm is stable under the selected operating conditions.","PeriodicalId":268430,"journal":{"name":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Stability evaluation of simplified Taiwan Power System connected with a large-scale offshore wind farm\",\"authors\":\"Li Wang, Che-Hao Chang, Cheng-Tai Wu, A. Prokhorov\",\"doi\":\"10.1109/IFEEC.2015.7361389\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the small-signal stability analysis results of the simplified Taiwan Power System connected with a high-capacity wind farm of 46 MW. The q-d axis equivalent-circuit model is employed to establish the complete system model of simplified Taiwan Power System connected with the wind farm under three-phase balanced loading conditions. The eigenvalue results at the specific operating point and the time-domain simulations of the studied integrated power system under a three-phase short-circuit fault are both performed. From the eigenvalues and time-domain results, it shows that the simplified Taiwan Power System connected with the high-capacity wind farm is stable under the selected operating conditions.\",\"PeriodicalId\":268430,\"journal\":{\"name\":\"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IFEEC.2015.7361389\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFEEC.2015.7361389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Stability evaluation of simplified Taiwan Power System connected with a large-scale offshore wind farm
This paper presents the small-signal stability analysis results of the simplified Taiwan Power System connected with a high-capacity wind farm of 46 MW. The q-d axis equivalent-circuit model is employed to establish the complete system model of simplified Taiwan Power System connected with the wind farm under three-phase balanced loading conditions. The eigenvalue results at the specific operating point and the time-domain simulations of the studied integrated power system under a three-phase short-circuit fault are both performed. From the eigenvalues and time-domain results, it shows that the simplified Taiwan Power System connected with the high-capacity wind farm is stable under the selected operating conditions.