{"title":"高功率密度UPS用高频变压器耦合谐振直流链路的空间电压矢量调制正弦三相逆变器","authors":"H. Yonemori, M. Michihira, M. Nakaoka","doi":"10.1109/TELESC.1994.4794371","DOIUrl":null,"url":null,"abstract":"Newly-improved Quasi-Resonant DC Link (QRDCL) three-phase voltage-sourced inverter circuit topology operating under a commutation principle of the high-frequency (HF) transformer-assisted Zero Voltage Switching (ZVS) is proposed. The basic operating principle of this power conversion circuit using Auxiliary Transformer-assisted QRDCL (TQRDCL) more suitable for CVCF/UPS, power active filter, switched-mode PWM converter, and new energy-interfaced power supplies for utility-interactive interconnection is presetted in this paper, Its operating characteristics are discussed and evaluated in terms of using the computer-aided simulating results. The experimental circuit is tested and examined for CVCF/UPS systems. This tested equipment is discussed for linear and non-linear electrical loads under the conditions of large load variations and voltage fluctuations from a practical point of view.","PeriodicalId":178715,"journal":{"name":"TELESCON '94 - The First International Telecommunications Energy Special Conference","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The State-of-Art Space-Voltage Vector Modulated Sinusoidal Three-Phase Inverter with High-Frequency Transformer-Coupled Resonant DC Link for High-Power Density UPS\",\"authors\":\"H. Yonemori, M. Michihira, M. Nakaoka\",\"doi\":\"10.1109/TELESC.1994.4794371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Newly-improved Quasi-Resonant DC Link (QRDCL) three-phase voltage-sourced inverter circuit topology operating under a commutation principle of the high-frequency (HF) transformer-assisted Zero Voltage Switching (ZVS) is proposed. The basic operating principle of this power conversion circuit using Auxiliary Transformer-assisted QRDCL (TQRDCL) more suitable for CVCF/UPS, power active filter, switched-mode PWM converter, and new energy-interfaced power supplies for utility-interactive interconnection is presetted in this paper, Its operating characteristics are discussed and evaluated in terms of using the computer-aided simulating results. The experimental circuit is tested and examined for CVCF/UPS systems. This tested equipment is discussed for linear and non-linear electrical loads under the conditions of large load variations and voltage fluctuations from a practical point of view.\",\"PeriodicalId\":178715,\"journal\":{\"name\":\"TELESCON '94 - The First International Telecommunications Energy Special Conference\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TELESCON '94 - The First International Telecommunications Energy Special Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TELESC.1994.4794371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TELESCON '94 - The First International Telecommunications Energy Special Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TELESC.1994.4794371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The State-of-Art Space-Voltage Vector Modulated Sinusoidal Three-Phase Inverter with High-Frequency Transformer-Coupled Resonant DC Link for High-Power Density UPS
Newly-improved Quasi-Resonant DC Link (QRDCL) three-phase voltage-sourced inverter circuit topology operating under a commutation principle of the high-frequency (HF) transformer-assisted Zero Voltage Switching (ZVS) is proposed. The basic operating principle of this power conversion circuit using Auxiliary Transformer-assisted QRDCL (TQRDCL) more suitable for CVCF/UPS, power active filter, switched-mode PWM converter, and new energy-interfaced power supplies for utility-interactive interconnection is presetted in this paper, Its operating characteristics are discussed and evaluated in terms of using the computer-aided simulating results. The experimental circuit is tested and examined for CVCF/UPS systems. This tested equipment is discussed for linear and non-linear electrical loads under the conditions of large load variations and voltage fluctuations from a practical point of view.