用于EV/HEV应用的六相交错双向dc-dc升压转换器的闭环控制

D. Schumacher, P. Magne, M. Preindl, B. Bilgin, A. Emadi
{"title":"用于EV/HEV应用的六相交错双向dc-dc升压转换器的闭环控制","authors":"D. Schumacher, P. Magne, M. Preindl, B. Bilgin, A. Emadi","doi":"10.1109/ITEC.2016.7520233","DOIUrl":null,"url":null,"abstract":"This paper discusses and implements a control strategy for a six-phase interleaved bidirectional dc-dc converter for a battery system for an HEV/EV application. First, basic control strategies of dc-dc converters are reviewed for interleaving and for bidirectional operation. Then, the two-loop average mode current control (AVGCCM) is used along with a unified control strategy for the bidirectional operation. A single unified controller is implemented for bidirectional operation along with active rectification for eliminating the discontinuous conduction mode (DCM). Both, techniques are analyzed in simulation and tested on a 5kW experimental setup.","PeriodicalId":280676,"journal":{"name":"2016 IEEE Transportation Electrification Conference and Expo (ITEC)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Closed loop control of a six phase interleaved bidirectional dc-dc boost converter for an EV/HEV application\",\"authors\":\"D. Schumacher, P. Magne, M. Preindl, B. Bilgin, A. Emadi\",\"doi\":\"10.1109/ITEC.2016.7520233\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses and implements a control strategy for a six-phase interleaved bidirectional dc-dc converter for a battery system for an HEV/EV application. First, basic control strategies of dc-dc converters are reviewed for interleaving and for bidirectional operation. Then, the two-loop average mode current control (AVGCCM) is used along with a unified control strategy for the bidirectional operation. A single unified controller is implemented for bidirectional operation along with active rectification for eliminating the discontinuous conduction mode (DCM). Both, techniques are analyzed in simulation and tested on a 5kW experimental setup.\",\"PeriodicalId\":280676,\"journal\":{\"name\":\"2016 IEEE Transportation Electrification Conference and Expo (ITEC)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Transportation Electrification Conference and Expo (ITEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITEC.2016.7520233\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Transportation Electrification Conference and Expo (ITEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITEC.2016.7520233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

本文讨论并实现了一种用于HEV/EV电池系统的六相交错双向dc-dc变换器的控制策略。首先,综述了直流-直流变换器的交错和双向运行的基本控制策略。然后,采用双环平均模式电流控制(AVGCCM)和统一的双向操作控制策略。采用单一的统一控制器实现双向操作,并采用主动整流消除不连续导通模式(DCM)。对这两种技术进行了仿真分析,并在5kW实验装置上进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Closed loop control of a six phase interleaved bidirectional dc-dc boost converter for an EV/HEV application
This paper discusses and implements a control strategy for a six-phase interleaved bidirectional dc-dc converter for a battery system for an HEV/EV application. First, basic control strategies of dc-dc converters are reviewed for interleaving and for bidirectional operation. Then, the two-loop average mode current control (AVGCCM) is used along with a unified control strategy for the bidirectional operation. A single unified controller is implemented for bidirectional operation along with active rectification for eliminating the discontinuous conduction mode (DCM). Both, techniques are analyzed in simulation and tested on a 5kW experimental setup.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信