A. Mishra, P. K. Nanda, Debiprasanna Das, A. Patra, Narayan Nahak, Lalit M. Sathapathy
{"title":"谐波与无功补偿并联无源滤波器的设计与分析","authors":"A. Mishra, P. K. Nanda, Debiprasanna Das, A. Patra, Narayan Nahak, Lalit M. Sathapathy","doi":"10.1109/APSIT58554.2023.10201759","DOIUrl":null,"url":null,"abstract":"The main cause of supply voltage distortion is due to the extensive use of power electronics based loads in almost all types of residential, commercial and industrial customer. The power electronics based loads draw harmonic current from the source. In order to reduce the harmonic currents entering into the distribution systems Passive filters are widely used. To present the complete design procedure of Shunt Passive Filter this article has been written again in this article a 5th, 7th single tuned and a 11th and 13th double tuned shunt passive filter is connected in a 3Φ three wire power system supplying power to a nonlinear load in order to reduce the harmonics and to compensate the reactive power. The performance parameters are obtained showing the better response after the connection Passive filter.","PeriodicalId":170044,"journal":{"name":"2023 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Analysis of Shunt Passive Filter for Harmonic and Reactive Power Compensation\",\"authors\":\"A. Mishra, P. K. Nanda, Debiprasanna Das, A. Patra, Narayan Nahak, Lalit M. Sathapathy\",\"doi\":\"10.1109/APSIT58554.2023.10201759\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main cause of supply voltage distortion is due to the extensive use of power electronics based loads in almost all types of residential, commercial and industrial customer. The power electronics based loads draw harmonic current from the source. In order to reduce the harmonic currents entering into the distribution systems Passive filters are widely used. To present the complete design procedure of Shunt Passive Filter this article has been written again in this article a 5th, 7th single tuned and a 11th and 13th double tuned shunt passive filter is connected in a 3Φ three wire power system supplying power to a nonlinear load in order to reduce the harmonics and to compensate the reactive power. The performance parameters are obtained showing the better response after the connection Passive filter.\",\"PeriodicalId\":170044,\"journal\":{\"name\":\"2023 International Conference in Advances in Power, Signal, and Information Technology (APSIT)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 International Conference in Advances in Power, Signal, and Information Technology (APSIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APSIT58554.2023.10201759\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APSIT58554.2023.10201759","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and Analysis of Shunt Passive Filter for Harmonic and Reactive Power Compensation
The main cause of supply voltage distortion is due to the extensive use of power electronics based loads in almost all types of residential, commercial and industrial customer. The power electronics based loads draw harmonic current from the source. In order to reduce the harmonic currents entering into the distribution systems Passive filters are widely used. To present the complete design procedure of Shunt Passive Filter this article has been written again in this article a 5th, 7th single tuned and a 11th and 13th double tuned shunt passive filter is connected in a 3Φ three wire power system supplying power to a nonlinear load in order to reduce the harmonics and to compensate the reactive power. The performance parameters are obtained showing the better response after the connection Passive filter.