B. Karaboce, Emel Çetin, H. Durmuş, Mithat Ozdingis, H. Korkmaz, Julide Altun, Serhan Argun
{"title":"聚焦超声作用下热电偶粘性加热效应的实验研究","authors":"B. Karaboce, Emel Çetin, H. Durmuş, Mithat Ozdingis, H. Korkmaz, Julide Altun, Serhan Argun","doi":"10.1109/MeMeA.2017.7985855","DOIUrl":null,"url":null,"abstract":"Realization of temperature characterization on focused ultrasound treatment devices by using tissue-mimicking phantom systems (Tissue-Mimicking Material, TMM) is indispensible in pre-clinical studies. In this survey, in order to examine the viscous heating effect of thermocouples, temperature rise due to excitation of a HIFU transducer has been measured by using two different types of T-type thermocouples embedded inside the TMM. In order to obtain the temperature values from the thermocouples more effectively, a PC-based multi-channel data acquisition and monitoring interface were developed by using LabVIEW graphical development platform. Measurements were carried out inside a TMM which has characteristics like human liver tissue. Temperature rise has been characterized for the different input ultrasonic powers (25 W, 38 W and 50 W) and frequencies (1,1 MHz and 3.3 MHz) and the time intervals applied (1 s, 2 s and 3 s). The temperature values obtained from two different types of T-type thermocouple were compared to each other and discrepancies between these two different thermocouple measurements were shown with the study.","PeriodicalId":235051,"journal":{"name":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Experimental investigations of viscous heating effect of thermocouples under focused ultrasound applications\",\"authors\":\"B. Karaboce, Emel Çetin, H. Durmuş, Mithat Ozdingis, H. Korkmaz, Julide Altun, Serhan Argun\",\"doi\":\"10.1109/MeMeA.2017.7985855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Realization of temperature characterization on focused ultrasound treatment devices by using tissue-mimicking phantom systems (Tissue-Mimicking Material, TMM) is indispensible in pre-clinical studies. In this survey, in order to examine the viscous heating effect of thermocouples, temperature rise due to excitation of a HIFU transducer has been measured by using two different types of T-type thermocouples embedded inside the TMM. In order to obtain the temperature values from the thermocouples more effectively, a PC-based multi-channel data acquisition and monitoring interface were developed by using LabVIEW graphical development platform. Measurements were carried out inside a TMM which has characteristics like human liver tissue. Temperature rise has been characterized for the different input ultrasonic powers (25 W, 38 W and 50 W) and frequencies (1,1 MHz and 3.3 MHz) and the time intervals applied (1 s, 2 s and 3 s). The temperature values obtained from two different types of T-type thermocouple were compared to each other and discrepancies between these two different thermocouple measurements were shown with the study.\",\"PeriodicalId\":235051,\"journal\":{\"name\":\"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2017.7985855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2017.7985855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental investigations of viscous heating effect of thermocouples under focused ultrasound applications
Realization of temperature characterization on focused ultrasound treatment devices by using tissue-mimicking phantom systems (Tissue-Mimicking Material, TMM) is indispensible in pre-clinical studies. In this survey, in order to examine the viscous heating effect of thermocouples, temperature rise due to excitation of a HIFU transducer has been measured by using two different types of T-type thermocouples embedded inside the TMM. In order to obtain the temperature values from the thermocouples more effectively, a PC-based multi-channel data acquisition and monitoring interface were developed by using LabVIEW graphical development platform. Measurements were carried out inside a TMM which has characteristics like human liver tissue. Temperature rise has been characterized for the different input ultrasonic powers (25 W, 38 W and 50 W) and frequencies (1,1 MHz and 3.3 MHz) and the time intervals applied (1 s, 2 s and 3 s). The temperature values obtained from two different types of T-type thermocouple were compared to each other and discrepancies between these two different thermocouple measurements were shown with the study.