{"title":"颈动脉b超图像中的血流生成","authors":"A. Hamou, M. El-Sakka","doi":"10.1109/ICIP.2004.1421730","DOIUrl":null,"url":null,"abstract":"This paper presents a new blood flow detection scheme, where a novel painting segmentation algorithm is utilized in order to achieve the accurate area of lumens, within carotid artery B-mode ultrasound images. The scheme allows for user-defined thresholding providing tolerance levels within the contour detection process in order to overcome crippling interference noise and degrading artifacts in ultrasound images. Since plaque buildup obstructs the flow of blood in the carotid artery, this scheme can identify these severe plaque-thickened inflamed regions, through detecting high and low levels of blood flow.","PeriodicalId":184798,"journal":{"name":"2004 International Conference on Image Processing, 2004. ICIP '04.","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Blood flow generation in B-mode ultrasound images of the carotid artery\",\"authors\":\"A. Hamou, M. El-Sakka\",\"doi\":\"10.1109/ICIP.2004.1421730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new blood flow detection scheme, where a novel painting segmentation algorithm is utilized in order to achieve the accurate area of lumens, within carotid artery B-mode ultrasound images. The scheme allows for user-defined thresholding providing tolerance levels within the contour detection process in order to overcome crippling interference noise and degrading artifacts in ultrasound images. Since plaque buildup obstructs the flow of blood in the carotid artery, this scheme can identify these severe plaque-thickened inflamed regions, through detecting high and low levels of blood flow.\",\"PeriodicalId\":184798,\"journal\":{\"name\":\"2004 International Conference on Image Processing, 2004. ICIP '04.\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 International Conference on Image Processing, 2004. ICIP '04.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIP.2004.1421730\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Conference on Image Processing, 2004. ICIP '04.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIP.2004.1421730","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Blood flow generation in B-mode ultrasound images of the carotid artery
This paper presents a new blood flow detection scheme, where a novel painting segmentation algorithm is utilized in order to achieve the accurate area of lumens, within carotid artery B-mode ultrasound images. The scheme allows for user-defined thresholding providing tolerance levels within the contour detection process in order to overcome crippling interference noise and degrading artifacts in ultrasound images. Since plaque buildup obstructs the flow of blood in the carotid artery, this scheme can identify these severe plaque-thickened inflamed regions, through detecting high and low levels of blood flow.