{"title":"面向非接触心电和脑电图的电容耦合传感器读出电路的设计与评估","authors":"Daniel Svard, A. Cichocki, A. Alvandpour","doi":"10.1109/BIOCAS.2010.5709631","DOIUrl":null,"url":null,"abstract":"Electrophysiological signal acquisition such as ECG and EEG play an important part in modern medical monitoring and diagnostics. The measurement of these very low-level, low-frequency signals are normally made from the skin with a directly coupled sensor utilizing a conductive gel to create a low resistance path for the charge. The application of the gel is tedious and time consuming as well as requiring a clinical environment and prevents long period measurements. In this paper, a contact-less, capacitively coupled sensor — without any need for gel — together with an electronic readout circuit using a PCB is presented. A design with a very high input impedance allows for measurements of signals with amplitudes down to a few tens of microvolts and at frequencies between a few hertz to tens of hertz. Measurements show that the circuit could detect an input signal of 25 μV at 10 Hz with an SNR of 9.7 dB.","PeriodicalId":440499,"journal":{"name":"2010 Biomedical Circuits and Systems Conference (BioCAS)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Design and evaluation of a capacitively coupled sensor readout circuit, toward contact-less ECG and EEG\",\"authors\":\"Daniel Svard, A. Cichocki, A. Alvandpour\",\"doi\":\"10.1109/BIOCAS.2010.5709631\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrophysiological signal acquisition such as ECG and EEG play an important part in modern medical monitoring and diagnostics. The measurement of these very low-level, low-frequency signals are normally made from the skin with a directly coupled sensor utilizing a conductive gel to create a low resistance path for the charge. The application of the gel is tedious and time consuming as well as requiring a clinical environment and prevents long period measurements. In this paper, a contact-less, capacitively coupled sensor — without any need for gel — together with an electronic readout circuit using a PCB is presented. A design with a very high input impedance allows for measurements of signals with amplitudes down to a few tens of microvolts and at frequencies between a few hertz to tens of hertz. Measurements show that the circuit could detect an input signal of 25 μV at 10 Hz with an SNR of 9.7 dB.\",\"PeriodicalId\":440499,\"journal\":{\"name\":\"2010 Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2010.5709631\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2010.5709631","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and evaluation of a capacitively coupled sensor readout circuit, toward contact-less ECG and EEG
Electrophysiological signal acquisition such as ECG and EEG play an important part in modern medical monitoring and diagnostics. The measurement of these very low-level, low-frequency signals are normally made from the skin with a directly coupled sensor utilizing a conductive gel to create a low resistance path for the charge. The application of the gel is tedious and time consuming as well as requiring a clinical environment and prevents long period measurements. In this paper, a contact-less, capacitively coupled sensor — without any need for gel — together with an electronic readout circuit using a PCB is presented. A design with a very high input impedance allows for measurements of signals with amplitudes down to a few tens of microvolts and at frequencies between a few hertz to tens of hertz. Measurements show that the circuit could detect an input signal of 25 μV at 10 Hz with an SNR of 9.7 dB.