{"title":"老年人手环心率值偏差优化算法研究","authors":"Yazhen Gu","doi":"10.1109/AEMCSE50948.2020.00028","DOIUrl":null,"url":null,"abstract":"In the study of wearable devices which can measure heart rate, the deviation of heart rate value will greatly affect the function of the bracelet. An optimized algorithm is proposed to determine the heart rate value and it's reasonable range by using behaviour recognition. The algorithm uses the combined acceleration, combined angular velocity and threshold to determine the three behavioral states of a person, including walking, running and stillness. The accuracy of the heart rate value was increased by 10% compared to the previous test data.","PeriodicalId":246841,"journal":{"name":"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)","volume":"360 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Optimized Algorithm for Heart Rate Value Deviation of Elderly Bracelet\",\"authors\":\"Yazhen Gu\",\"doi\":\"10.1109/AEMCSE50948.2020.00028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the study of wearable devices which can measure heart rate, the deviation of heart rate value will greatly affect the function of the bracelet. An optimized algorithm is proposed to determine the heart rate value and it's reasonable range by using behaviour recognition. The algorithm uses the combined acceleration, combined angular velocity and threshold to determine the three behavioral states of a person, including walking, running and stillness. The accuracy of the heart rate value was increased by 10% compared to the previous test data.\",\"PeriodicalId\":246841,\"journal\":{\"name\":\"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)\",\"volume\":\"360 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEMCSE50948.2020.00028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Advanced Electronic Materials, Computers and Software Engineering (AEMCSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEMCSE50948.2020.00028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Optimized Algorithm for Heart Rate Value Deviation of Elderly Bracelet
In the study of wearable devices which can measure heart rate, the deviation of heart rate value will greatly affect the function of the bracelet. An optimized algorithm is proposed to determine the heart rate value and it's reasonable range by using behaviour recognition. The algorithm uses the combined acceleration, combined angular velocity and threshold to determine the three behavioral states of a person, including walking, running and stillness. The accuracy of the heart rate value was increased by 10% compared to the previous test data.